bridge ------ .. osdx:cfgcmd:: interfaces bridge .. raw:: html SDE M10-Smart M2 RS420 AresC640 Bridge interface name :arg brN: Bridge interface name :instances: Multiple .. osdx:cfgcmd:: interfaces bridge address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP address :arg ipv6cidr: IPv6 address and prefix length :arg dhcpv6: Dynamic Host Configuration Protocol for IPv6 :arg ipv4cidr: IPv4 address and prefix length :arg dhcp: Dynamic Host Configuration Protocol :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ageing .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval addresses are retained :arg u32: Disable retaining address in bridge (always flood) (0) :arg u32: Address aging time for bridge seconds (10-1000000) .. osdx:cfgcmd:: interfaces bridge alarm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable or disable alarm according the link state .. osdx:cfgcmd:: interfaces bridge alarm down .. raw:: html SDE M10-Smart M2 RS420 AresC640 Alarm to be enabled if the link is down :ref Reference: system alarm * .. osdx:cfgcmd:: interfaces bridge description .. raw:: html SDE M10-Smart M2 RS420 AresC640 Description :arg id: "Interface description is too long (limit 256 characters)" (1-256) .. osdx:cfgcmd:: interfaces bridge dhcp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Dynamic Host Configuration Protocol configuration .. osdx:cfgcmd:: interfaces bridge dhcp client .. raw:: html SDE M10-Smart M2 RS420 AresC640 DHCP client configuration .. osdx:cfgcmd:: interfaces bridge dhcp client fallback .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv4cidr: Fallback IP address :arg ipv6cidr: Fallback IP address .. osdx:cfgcmd:: interfaces bridge dhcp client rfc3442-routes .. raw:: html SDE M10-Smart M2 RS420 AresC640 Install RFC3442 routes received from DHCP server .. osdx:cfgcmd:: interfaces bridge dhcp client send .. raw:: html SDE M10-Smart M2 RS420 AresC640 Send user-defined options to the DHCP server .. osdx:cfgcmd:: interfaces bridge dhcp client send dhcp-client-identifier .. raw:: html SDE M10-Smart M2 RS420 AresC640 Include the 'dhcp-client-identifier' option :instances: Unique .. osdx:cfgcmd:: interfaces bridge dhcp client send dhcp-client-identifier base-mac .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use device base mac as identifier .. osdx:cfgcmd:: interfaces bridge dhcp client send dhcp-client-identifier serial-number .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use device serial number as identifier .. osdx:cfgcmd:: interfaces bridge dhcp client send dhcp-client-identifier string .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use a string as identifier :arg id: Identifier string (1-255) .. osdx:cfgcmd:: interfaces bridge dhcp client send vendor-class-identifier .. raw:: html SDE M10-Smart M2 RS420 AresC640 Include the 'vendor-class-identifier' option :instances: Unique .. osdx:cfgcmd:: interfaces bridge dhcp client send vendor-class-identifier string .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use a string as identifier :arg id: Identifier string (1-255) .. osdx:cfgcmd:: interfaces bridge dhcpv6 .. raw:: html SDE M10-Smart M2 RS420 AresC640 Dynamic Host Configuration Protocol v6 configuration .. osdx:cfgcmd:: interfaces bridge dhcpv6 client .. raw:: html SDE M10-Smart M2 RS420 AresC640 DHCPv6 client configuration .. osdx:cfgcmd:: interfaces bridge dhcpv6 client parameters-only .. raw:: html SDE M10-Smart M2 RS420 AresC640 Acquire only config parameters, not address .. osdx:cfgcmd:: interfaces bridge dhcpv6 client send .. raw:: html SDE M10-Smart M2 RS420 AresC640 Send user-defined options to the DHCPv6 server .. osdx:cfgcmd:: interfaces bridge dhcpv6 client send duid .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: DHCPv6 DUID to be sent by dhcpv6 client .. osdx:cfgcmd:: interfaces bridge dhcpv6 client temporary .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 "temporary" address .. osdx:cfgcmd:: interfaces bridge disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable interface .. osdx:cfgcmd:: interfaces bridge disable advisor .. raw:: html SDE M10-Smart M2 RS420 AresC640 Advisor to enable or disable the interface :ref Reference: system advisor * .. osdx:cfgcmd:: interfaces bridge disable-offload .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable offload engine in this interface .. osdx:cfgcmd:: interfaces bridge flow .. raw:: html SDE M10-Smart M2 RS420 AresC640 Active netflow on interface .. osdx:cfgcmd:: interfaces bridge flow egress .. raw:: html SDE M10-Smart M2 RS420 AresC640 Active output traffic .. osdx:cfgcmd:: interfaces bridge flow egress selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge flow ingress .. raw:: html SDE M10-Smart M2 RS420 AresC640 Active input traffic .. osdx:cfgcmd:: interfaces bridge flow ingress selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge hardware-offload .. raw:: html M10-Smart M2 RS420 :arg id: Enable switch offloading :instances: Multiple .. osdx:cfgcmd:: interfaces bridge hardware-offload denied-macs .. raw:: html M10-Smart M2 RS420 :arg anymacaddr: Denied Macs list :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ip .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv4 routing parameters .. osdx:cfgcmd:: interfaces bridge ip arp .. raw:: html SDE M10-Smart M2 RS420 AresC640 ARP options .. osdx:cfgcmd:: interfaces bridge ip arp ignore .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable arp-ignore on this interface .. osdx:cfgcmd:: interfaces bridge ip arp no-filter .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable arp-filter on this interface .. osdx:cfgcmd:: interfaces bridge ip arp no-notify .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable arp_notify on this interface .. osdx:cfgcmd:: interfaces bridge ip arp proxy .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable proxy-arp on this interface .. osdx:cfgcmd:: interfaces bridge ip arp pvlan-proxy .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable private VLAN proxy ARP on this interface .. osdx:cfgcmd:: interfaces bridge ip arp static .. raw:: html SDE M10-Smart M2 RS420 AresC640 Static ARP translation :arg ipv4: IPv4 address to add in ARP table :instances: Multiple :ref Required: .. osdx:cfgcmd:: interfaces bridge ip arp static mac .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg macaddr: MAC address .. osdx:cfgcmd:: interfaces bridge ip arp timeout .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: ARP cache entry timeout in seconds .. osdx:cfgcmd:: interfaces bridge ip igmp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Internet Group Management Protocol (IGMP) parameters .. osdx:cfgcmd:: interfaces bridge ip igmp join .. raw:: html SDE M10-Smart M2 RS420 AresC640 Join multicast group :arg ipv4: Join multicast group on this interface .. osdx:cfgcmd:: interfaces bridge ip igmp last-member-query-count .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP last member query count :arg u32: IGMP last member query count (1-255) .. osdx:cfgcmd:: interfaces bridge ip igmp last-member-query-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP last member query interval :arg u32: IGMP last member query interval in deciseconds (1-65535) .. osdx:cfgcmd:: interfaces bridge ip igmp query-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP query interval :arg u32: IGMP query interval in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge ip igmp query-max-response-time .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP query response timeout value :arg u32: IGMP query response timeout value in deciseconds (1-65535) .. osdx:cfgcmd:: interfaces bridge ip igmp version .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP version :arg u32: IGMP version used on this interface (2-3) .. osdx:cfgcmd:: interfaces bridge ip multicast .. raw:: html SDE M10-Smart M2 RS420 AresC640 Multicast parameters .. osdx:cfgcmd:: interfaces bridge ip multicast boundary-list .. raw:: html SDE M10-Smart M2 RS420 AresC640 Prefix-list to control for which groups to accept or ignore received PIM join or IGMP report messages :ref Reference: protocols ip prefix-list * .. osdx:cfgcmd:: interfaces bridge ip ospf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Open Shortest Path First (OSPF) parameters .. osdx:cfgcmd:: interfaces bridge ip ospf authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 OSPF interface authentication .. osdx:cfgcmd:: interfaces bridge ip ospf authentication encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: Encrypted password .. osdx:cfgcmd:: interfaces bridge ip ospf authentication message-digest .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 authentication parameters :arg id: MD5 ID number (1-255) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ip ospf authentication message-digest encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: MD5 encrypted key .. osdx:cfgcmd:: interfaces bridge ip ospf authentication message-digest password .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 key :arg txt: MD5 Key (1-16) .. osdx:cfgcmd:: interfaces bridge ip ospf authentication password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Plain text password .. osdx:cfgcmd:: interfaces bridge ip ospf bandwidth .. raw:: html SDE M10-Smart M2 RS420 AresC640 Bandwidth of interface (kilobits/sec) :arg u32: Bandwidth in kilobits/sec (for calculating OSPF cost) (1-10000000) .. osdx:cfgcmd:: interfaces bridge ip ospf cost .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interface cost :arg u32: OSPF interface cost (1-65535) .. osdx:cfgcmd:: interfaces bridge ip ospf dead-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval after which neighbor is dead :arg u32: OSPF dead interval in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge ip ospf hello-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between hello packets :arg u32: Interval between OSPF hello packets in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge ip ospf mtu-ignore .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable Maximum Transmission Unit (MTU) mismatch detection .. osdx:cfgcmd:: interfaces bridge ip ospf network .. raw:: html SDE M10-Smart M2 RS420 AresC640 Network type :arg broadcast: Broadcast network type :arg non-broadcast: Non-broadcast network type :arg point-to-multipoint: Point-to-multipoint network type :arg point-to-point: Point-to-point network type .. osdx:cfgcmd:: interfaces bridge ip ospf priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Router priority :arg u32: Priority (0-255) .. osdx:cfgcmd:: interfaces bridge ip ospf retransmit-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between retransmitting lost link state advertisements :arg u32: Retransmit interval in seconds (3-65535) .. osdx:cfgcmd:: interfaces bridge ip ospf transmit-delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Link state transmit delay :arg u32: Transmit delay in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge ip pim .. raw:: html SDE M10-Smart M2 RS420 AresC640 Protocol Independent Multicast (PIM) parameters .. osdx:cfgcmd:: interfaces bridge ip pim disable-bsm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable sending and receiving bootstrap messages .. osdx:cfgcmd:: interfaces bridge ip pim disable-unicast-bsm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable sending and receiving unicast bootstrap messages .. osdx:cfgcmd:: interfaces bridge ip pim drpriority .. raw:: html SDE M10-Smart M2 RS420 AresC640 PIM Designated Router (DR) priority :arg u32: PIM DR priority for the interface (1-4294967295) .. osdx:cfgcmd:: interfaces bridge ip pim hello .. raw:: html SDE M10-Smart M2 RS420 AresC640 PIM hello interval :arg u32: PIM hello interval in seconds (1-255) .. osdx:cfgcmd:: interfaces bridge ip pim passive .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable sending and receiving all PIM control messages (such as: ASSERT, BSM, HELLO, JOIN, PRUNE, REGISTER, REGISTER-STOP) .. osdx:cfgcmd:: interfaces bridge ip reverse-path-filter .. raw:: html SDE M10-Smart M2 RS420 AresC640 Policy for source validation by reversed path, as specified in RFC3704 :arg strict: Enable Strict Reverse Path Forwarding as defined in RFC3704 :arg loose: Enable Loose Reverse Path Forwarding as defined in RFC3704 :arg disable: No source validation .. osdx:cfgcmd:: interfaces bridge ip rip .. raw:: html SDE M10-Smart M2 RS420 AresC640 Routing Information Protocol (RIP) parameters .. osdx:cfgcmd:: interfaces bridge ip rip authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 Authentication method .. osdx:cfgcmd:: interfaces bridge ip rip authentication encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: Encrypted password .. osdx:cfgcmd:: interfaces bridge ip rip authentication message-digest .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 authentication parameters :arg u32: MD5 ID number (1-255) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ip rip authentication message-digest encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: MD5 encrypted key .. osdx:cfgcmd:: interfaces bridge ip rip authentication message-digest password .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 key :arg txt: MD5 Key (1-16) .. osdx:cfgcmd:: interfaces bridge ip rip authentication password .. raw:: html SDE M10-Smart M2 RS420 AresC640 Plain text password :arg txt: Plain text password (1-16) .. osdx:cfgcmd:: interfaces bridge ip rip split-horizon .. raw:: html SDE M10-Smart M2 RS420 AresC640 Split horizon parameters .. osdx:cfgcmd:: interfaces bridge ip rip split-horizon disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable split horizon on specified interface .. osdx:cfgcmd:: interfaces bridge ip rip split-horizon poison-reverse .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable poison reverse for split-horizon .. osdx:cfgcmd:: interfaces bridge ipv6 .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 routing parameters .. osdx:cfgcmd:: interfaces bridge ipv6 address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 address auto-configuration modes .. osdx:cfgcmd:: interfaces bridge ipv6 address autoconf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable acquisition of IPv6 address using stateless autoconfig .. osdx:cfgcmd:: interfaces bridge ipv6 address eui64 .. raw:: html SDE M10-Smart M2 RS420 AresC640 Assign IPv6 address using EUI-64 based on MAC address :arg ipv6net: 64-bit IPv6 prefix to use with EUI-64 to make address :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ipv6 address prefix-from-provider .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: IPv6 from Learned Prefix :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ipv6 address prefix-from-provider ifc-ID .. raw:: html SDE M10-Smart M2 RS420 AresC640 Assign IPv6 address using Learned Prefixes :arg <: 64-bit IPv6 prefix (:h:h:h:h/64>) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ipv6 dhcp-client-pd .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: Name of learned prefix from provider .. osdx:cfgcmd:: interfaces bridge ipv6 disable-forwarding .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable IPv6 forwarding on this interface only .. osdx:cfgcmd:: interfaces bridge ipv6 dup-addr-detect-transmits .. raw:: html SDE M10-Smart M2 RS420 AresC640 Number of NS messages to send while performing DAD :arg u32: Number of NS messages to send while performing DAD (0-2147483647) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 Open Shortest Path First (OSPFv3) parameters .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 area .. raw:: html SDE M10-Smart M2 RS420 AresC640 OSPFv3 Area :arg u32: OSPFv3 area in decimal notation (0-4294967295) :arg ipv4: OSPFv3 area in dotted decimal notation .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 OSPFv3 interface authentication :instances: Unique .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 authentication hmac-sha-256 .. raw:: html SDE M10-Smart M2 RS420 AresC640 HMAC-SHA-256 authentication parameters :arg u32: HMAC-SHA-256 key ID (1-65535) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 authentication hmac-sha-256 encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: HMAC-SHA-256 encrypted password .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 authentication hmac-sha-256 password .. raw:: html SDE M10-Smart M2 RS420 AresC640 HMAC-SHA-256 plain text password :arg txt: HMAC-SHA-256 plain text password (1-16) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 authentication md5 .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 authentication parameters :arg u32: MD5 key ID (1-65535) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 authentication md5 encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: MD5 encrypted password .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 authentication md5 password .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 plain text password :arg txt: MD5 plain text password (1-16) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 cost .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interface cost :arg u32: OSPFv3 cost (1-65535) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 dead-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval after which neighbor is declared dead :arg u32: Neighbor dead interval in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 hello-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between hello packets :arg u32: Interval between OSPFv3 hello packets in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 ifmtu .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interface MTU :arg u32: Interface MTU value (1-65535) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 instance-id .. raw:: html SDE M10-Smart M2 RS420 AresC640 Instance identifier :arg u32: Instance ID (0-255) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 mtu-ignore .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable Maximum Transmission Unit mismatch detection .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 network .. raw:: html SDE M10-Smart M2 RS420 AresC640 Network type :arg broadcast: Broadcast network type :arg point-to-point: Point-to-point network type .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 passive .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable forming of adjacency .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Router priority :arg u32: Priority (0-255) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 retransmit-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between retransmitting lost link state advertisements :arg u32: Retransmit interval in seconds (3-65535) .. osdx:cfgcmd:: interfaces bridge ipv6 ospfv3 transmit-delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Link state transmit delay :arg u32: Link state transmit delay in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge ipv6 ripng .. raw:: html SDE M10-Smart M2 RS420 AresC640 Routing Information Protocol (RIPng) .. osdx:cfgcmd:: interfaces bridge ipv6 ripng split-horizon .. raw:: html SDE M10-Smart M2 RS420 AresC640 Split horizon parameters .. osdx:cfgcmd:: interfaces bridge ipv6 ripng split-horizon disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable split horizon .. osdx:cfgcmd:: interfaces bridge ipv6 ripng split-horizon poison-reverse .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable poison reverse for split-horizon .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert .. raw:: html SDE M10-Smart M2 RS420 AresC640 Configure parameters for sending Router Advertisements (RAs) .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert cur-hop-limit .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to be placed in the Current Hop Limit field in RAs :arg u32: Value to place in the Current Hop Limit field in RAs (0-255) .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert default-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to be placed in Router Lifetime field in RAs :arg u32: Value in seconds to be placed in Router Lifetime field in RAs (4-9000) :arg u32: This means "not a default router", in Router Lifetime field (0) .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert default-preference .. raw:: html SDE M10-Smart M2 RS420 AresC640 Default router preference :arg low: Default router is low preference :arg medium: Default router is medium preference :arg high: Default router is high preference .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert link-mtu .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value of link MTU to place in RAs :arg u32: Do not send MTU options in RAs (0) :arg u32: Value of link MTU to place in RAs (1280-2147483647) .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert managed-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Value for "managed address configuration" flag in RAs .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert max-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Maximum interval between unsolicited multicast RAs :arg u32: Maximum interval in seconds between unsolicited multicast RAs (4-1800) .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert min-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Minimum interval between unsolicited multicast RAs :arg u32: Minimum interval in seconds between unsolicited multicast RAs (3-1350) .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert name-server .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv6: IPv6 address of a Recursive DNS Server :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert other-config-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Value to be placed in the "other configuration" flag in RAs .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert prefix .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 prefix to be advertised in Router Advertisements (RAs) :arg ipv6net: IPv6 prefix to be advertized in Router Advertisements (RAs) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert prefix autonomous-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Whether prefix can be used for address auto-configuration .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert prefix on-link-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Flag that prefix can be used for on-link determination .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert prefix preferred-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain preferred :arg u32: Time in seconds that the prefix will remain preferred (0-2147483647) :arg infinity: Prefix will remain preferred forever .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert prefix valid-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain valid :arg u32: Time in seconds that the prefix will remain valid (0-2147483647) :arg infinity: Prefix will remain valid forever .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert reachable-time .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to be placed in "Reachable Time" field in RAs :arg u32: Reachable Time value in RAs (in milliseconds) (1-3600000) :arg u32: Reachable Time 0 (i.e., unspecified by this router) (0) .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert retrans-timer .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to place in "Retrans Timer" field in RAs. :arg u32: Value in milliseconds to place in "Retrans Timer" field in RAs (0-2147483647) .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert send-advert .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Enable/disable sending RAs .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert used-prefixes .. raw:: html SDE M10-Smart M2 RS420 AresC640 Delegate prefixes used on the interface .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert used-prefixes autonomous-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Whether prefix can be used for address auto-configuration .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert used-prefixes on-link-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Flag that prefix can be used for on-link determination .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert used-prefixes preferred-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain preferred :arg u32: Time in seconds that the prefix will remain preferred (0-2147483647) :arg infinity: Prefix will remain preferred forever .. osdx:cfgcmd:: interfaces bridge ipv6 router-advert used-prefixes valid-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain valid :arg u32: Time in seconds that the prefix will remain valid (0-2147483647) :arg infinity: Prefix will remain valid forever .. osdx:cfgcmd:: interfaces bridge mac .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg macaddr: Media Access Control (MAC) address :arg ifc: Media Access Control (MAC) address .. osdx:cfgcmd:: interfaces bridge multicast .. raw:: html SDE M10-Smart M2 RS420 AresC640 Multicast configuration .. osdx:cfgcmd:: interfaces bridge multicast querier .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable IGMP/MLD querier If enabled, the bridge will send multicast queries .. osdx:cfgcmd:: interfaces bridge multicast snooping .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable multicast snooping Listen to Internet Group Management Protocol (IGMP) network traffic .. osdx:cfgcmd:: interfaces bridge stp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable STP (Spanning Tree Protocol) .. osdx:cfgcmd:: interfaces bridge stp forwarding-delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Bridge forwarding delay :arg u32: STP forwarding delay in seconds (4-30) .. osdx:cfgcmd:: interfaces bridge stp hello-time .. raw:: html SDE M10-Smart M2 RS420 AresC640 Hello packet advertisement interval :arg u32: Advertisement interval in seconds (1-10) .. osdx:cfgcmd:: interfaces bridge stp max-age .. raw:: html SDE M10-Smart M2 RS420 AresC640 Bridge maximum age :arg u32: Time in seconds (6-40) .. osdx:cfgcmd:: interfaces bridge stp priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Bridge priority This metric is used in the designated port and root port selection algorithms :arg u32: Bridge priority (0-15) .. osdx:cfgcmd:: interfaces bridge stp version .. raw:: html SDE M10-Smart M2 RS420 AresC640 Specific STP protocol version :arg stp: Spanning Tree Protocol (IEEE 802.1D) :arg rstp: Rapid Spanning Tree Protocol (IEEE 802.1W) .. osdx:cfgcmd:: interfaces bridge tcp-mss .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Change tcp-mss value .. osdx:cfgcmd:: interfaces bridge traffic .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic processing options .. osdx:cfgcmd:: interfaces bridge traffic control .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic control for interface .. osdx:cfgcmd:: interfaces bridge traffic control in .. raw:: html SDE M10-Smart M2 RS420 AresC640 Ingress traffic control for interface :ref Reference: traffic control * .. osdx:cfgcmd:: interfaces bridge traffic control out .. raw:: html SDE M10-Smart M2 RS420 AresC640 Egress traffic control for interface :ref Reference: traffic control * .. osdx:cfgcmd:: interfaces bridge traffic nat .. raw:: html SDE M10-Smart M2 RS420 AresC640 Network Address Translation (NAT) parameters .. osdx:cfgcmd:: interfaces bridge traffic nat destination .. raw:: html SDE M10-Smart M2 RS420 AresC640 Destination NAT settings .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule .. raw:: html SDE M10-Smart M2 RS420 AresC640 Rule number for NAT :arg u32: Number for this NAT rule (1-9999) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP address, subnet, range or redirect :arg ipv4: NAT to the specified IP address :arg ipv4net: NAT to the specified network address :arg ipv4range: NAT to the specified IP range :arg redirect: NAT to the interface address .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule description .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Rule description .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule log .. raw:: html SDE M10-Smart M2 RS420 AresC640 Log packets to which this rule has been applied .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule log level .. raw:: html SDE M10-Smart M2 RS420 AresC640 Loggin level :arg emerg: Emergency messages :arg alert: Urgent messages :arg crit: Critical messages :arg err: Error messages :arg warn: Warning messages :arg notice: Messages for further investigation :arg info: Informational messages :arg debug: Debug messages .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule log prefix .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Log message prefix text, up to 29 characters .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule network .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP prefix to use in translation (host part is kept) :arg ipv4net: NAT to the specified network address, host part of the address will remain unchanged .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule port .. raw:: html SDE M10-Smart M2 RS420 AresC640 NAT port :arg u32: Port to use in PAT (1-65535) :arg range: Port range (pool, for example, 1001-1005) .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule protocol .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: NAT transport protocol .. osdx:cfgcmd:: interfaces bridge traffic nat destination rule selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge traffic nat source .. raw:: html SDE M10-Smart M2 RS420 AresC640 Source NAT settings .. osdx:cfgcmd:: interfaces bridge traffic nat source rule .. raw:: html SDE M10-Smart M2 RS420 AresC640 Rule number for NAT :arg u32: Number for this NAT rule (1-9999) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge traffic nat source rule address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP address, subnet, range or masquerade :arg ipv4: NAT to the specified IP address :arg ipv4net: NAT to the specified network address :arg ipv4range: NAT to the specified IP range :arg masquerade: NAT to the interface address .. osdx:cfgcmd:: interfaces bridge traffic nat source rule description .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Rule description .. osdx:cfgcmd:: interfaces bridge traffic nat source rule log .. raw:: html SDE M10-Smart M2 RS420 AresC640 Log packets to which this rule has been applied .. osdx:cfgcmd:: interfaces bridge traffic nat source rule log level .. raw:: html SDE M10-Smart M2 RS420 AresC640 Loggin level :arg emerg: Emergency messages :arg alert: Urgent messages :arg crit: Critical messages :arg err: Error messages :arg warn: Warning messages :arg notice: Messages for further investigation :arg info: Informational messages :arg debug: Debug messages .. osdx:cfgcmd:: interfaces bridge traffic nat source rule log prefix .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Log message prefix text, up to 29 characters .. osdx:cfgcmd:: interfaces bridge traffic nat source rule network .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP prefix to use in translation (host part is kept) :arg ipv4net: NAT to the specified network address, host part of the address will remain unchanged .. osdx:cfgcmd:: interfaces bridge traffic nat source rule port .. raw:: html SDE M10-Smart M2 RS420 AresC640 NAT port :arg u32: Port to use in PAT (1-65535) :arg range: Port range (pool, for example, 1001-1005) .. osdx:cfgcmd:: interfaces bridge traffic nat source rule protocol .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: NAT transport protocol .. osdx:cfgcmd:: interfaces bridge traffic nat source rule selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge traffic policy .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic policy rulesets for interface .. osdx:cfgcmd:: interfaces bridge traffic policy in .. raw:: html SDE M10-Smart M2 RS420 AresC640 Input traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge traffic policy in priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed before NAT :arg high: Second policy executed before NAT :arg low: First policy executed after NAT :arg very-low: Second policy executed after NAT .. osdx:cfgcmd:: interfaces bridge traffic policy local-in .. raw:: html SDE M10-Smart M2 RS420 AresC640 Local input traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge traffic policy local-in priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed :arg high: Second policy executed :arg low: Third policy executed :arg very-low: Fourth policy executed .. osdx:cfgcmd:: interfaces bridge traffic policy local-out .. raw:: html SDE M10-Smart M2 RS420 AresC640 Local output traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge traffic policy local-out priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed :arg high: Second policy executed :arg low: Third policy executed :arg very-low: Fourth policy executed .. osdx:cfgcmd:: interfaces bridge traffic policy out .. raw:: html SDE M10-Smart M2 RS420 AresC640 Output traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge traffic policy out priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed before NAT :arg high: Second policy executed before NAT :arg low: First policy executed after NAT :arg very-low: Second policy executed after NAT .. osdx:cfgcmd:: interfaces bridge traffic zone .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic zone associated with this interface :ref Reference: traffic zone * .. osdx:cfgcmd:: interfaces bridge vif .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual Local Area Network (VLAN) ID :arg u32: VLAN ID (1-4094) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP address :arg ipv6cidr: IPv6 address and prefix length :arg dhcpv6: Dynamic Host Configuration Protocol for IPv6 :arg ipv4cidr: IPv4 address and prefix length :arg dhcp: Dynamic Host Configuration Protocol :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif alarm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable or disable alarm according the link state .. osdx:cfgcmd:: interfaces bridge vif alarm down .. raw:: html SDE M10-Smart M2 RS420 AresC640 Alarm to be enabled if the link is down :ref Reference: system alarm * .. osdx:cfgcmd:: interfaces bridge vif description .. raw:: html SDE M10-Smart M2 RS420 AresC640 Description :arg id: "Interface description is too long (limit 256 characters)" (1-256) .. osdx:cfgcmd:: interfaces bridge vif dhcp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Dynamic Host Configuration Protocol configuration .. osdx:cfgcmd:: interfaces bridge vif dhcp client .. raw:: html SDE M10-Smart M2 RS420 AresC640 DHCP client configuration .. osdx:cfgcmd:: interfaces bridge vif dhcp client fallback .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv4cidr: Fallback IP address :arg ipv6cidr: Fallback IP address .. osdx:cfgcmd:: interfaces bridge vif dhcp client rfc3442-routes .. raw:: html SDE M10-Smart M2 RS420 AresC640 Install RFC3442 routes received from DHCP server .. osdx:cfgcmd:: interfaces bridge vif dhcp client send .. raw:: html SDE M10-Smart M2 RS420 AresC640 Send user-defined options to the DHCP server .. osdx:cfgcmd:: interfaces bridge vif dhcp client send dhcp-client-identifier .. raw:: html SDE M10-Smart M2 RS420 AresC640 Include the 'dhcp-client-identifier' option :instances: Unique .. osdx:cfgcmd:: interfaces bridge vif dhcp client send dhcp-client-identifier base-mac .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use device base mac as identifier .. osdx:cfgcmd:: interfaces bridge vif dhcp client send dhcp-client-identifier serial-number .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use device serial number as identifier .. osdx:cfgcmd:: interfaces bridge vif dhcp client send dhcp-client-identifier string .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use a string as identifier :arg id: Identifier string (1-255) .. osdx:cfgcmd:: interfaces bridge vif dhcp client send vendor-class-identifier .. raw:: html SDE M10-Smart M2 RS420 AresC640 Include the 'vendor-class-identifier' option :instances: Unique .. osdx:cfgcmd:: interfaces bridge vif dhcp client send vendor-class-identifier string .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use a string as identifier :arg id: Identifier string (1-255) .. osdx:cfgcmd:: interfaces bridge vif dhcpv6 .. raw:: html SDE M10-Smart M2 RS420 AresC640 Dynamic Host Configuration Protocol v6 configuration .. osdx:cfgcmd:: interfaces bridge vif dhcpv6 client .. raw:: html SDE M10-Smart M2 RS420 AresC640 DHCPv6 client configuration .. osdx:cfgcmd:: interfaces bridge vif dhcpv6 client parameters-only .. raw:: html SDE M10-Smart M2 RS420 AresC640 Acquire only config parameters, not address .. osdx:cfgcmd:: interfaces bridge vif dhcpv6 client send .. raw:: html SDE M10-Smart M2 RS420 AresC640 Send user-defined options to the DHCPv6 server .. osdx:cfgcmd:: interfaces bridge vif dhcpv6 client send duid .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: DHCPv6 DUID to be sent by dhcpv6 client .. osdx:cfgcmd:: interfaces bridge vif dhcpv6 client temporary .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 "temporary" address .. osdx:cfgcmd:: interfaces bridge vif disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable interface .. osdx:cfgcmd:: interfaces bridge vif disable advisor .. raw:: html SDE M10-Smart M2 RS420 AresC640 Advisor to enable or disable the interface :ref Reference: system advisor * .. osdx:cfgcmd:: interfaces bridge vif disable-offload .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable offload engine in this interface .. osdx:cfgcmd:: interfaces bridge vif ethertype .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Set VLAN protocol .. osdx:cfgcmd:: interfaces bridge vif flow .. raw:: html SDE M10-Smart M2 RS420 AresC640 Active netflow on interface .. osdx:cfgcmd:: interfaces bridge vif flow egress .. raw:: html SDE M10-Smart M2 RS420 AresC640 Active output traffic .. osdx:cfgcmd:: interfaces bridge vif flow egress selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge vif flow ingress .. raw:: html SDE M10-Smart M2 RS420 AresC640 Active input traffic .. osdx:cfgcmd:: interfaces bridge vif flow ingress selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge vif ip .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv4 routing parameters .. osdx:cfgcmd:: interfaces bridge vif ip arp .. raw:: html SDE M10-Smart M2 RS420 AresC640 ARP options .. osdx:cfgcmd:: interfaces bridge vif ip arp ignore .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable arp-ignore on this interface .. osdx:cfgcmd:: interfaces bridge vif ip arp no-filter .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable arp-filter on this interface .. osdx:cfgcmd:: interfaces bridge vif ip arp no-notify .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable arp_notify on this interface .. osdx:cfgcmd:: interfaces bridge vif ip arp proxy .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable proxy-arp on this interface .. osdx:cfgcmd:: interfaces bridge vif ip arp pvlan-proxy .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable private VLAN proxy ARP on this interface .. osdx:cfgcmd:: interfaces bridge vif ip arp static .. raw:: html SDE M10-Smart M2 RS420 AresC640 Static ARP translation :arg ipv4: IPv4 address to add in ARP table :instances: Multiple :ref Required: .. osdx:cfgcmd:: interfaces bridge vif ip arp static mac .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg macaddr: MAC address .. osdx:cfgcmd:: interfaces bridge vif ip arp timeout .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: ARP cache entry timeout in seconds .. osdx:cfgcmd:: interfaces bridge vif ip igmp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Internet Group Management Protocol (IGMP) parameters .. osdx:cfgcmd:: interfaces bridge vif ip igmp join .. raw:: html SDE M10-Smart M2 RS420 AresC640 Join multicast group :arg ipv4: Join multicast group on this interface .. osdx:cfgcmd:: interfaces bridge vif ip igmp last-member-query-count .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP last member query count :arg u32: IGMP last member query count (1-255) .. osdx:cfgcmd:: interfaces bridge vif ip igmp last-member-query-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP last member query interval :arg u32: IGMP last member query interval in deciseconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ip igmp query-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP query interval :arg u32: IGMP query interval in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ip igmp query-max-response-time .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP query response timeout value :arg u32: IGMP query response timeout value in deciseconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ip igmp version .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP version :arg u32: IGMP version used on this interface (2-3) .. osdx:cfgcmd:: interfaces bridge vif ip multicast .. raw:: html SDE M10-Smart M2 RS420 AresC640 Multicast parameters .. osdx:cfgcmd:: interfaces bridge vif ip multicast boundary-list .. raw:: html SDE M10-Smart M2 RS420 AresC640 Prefix-list to control for which groups to accept or ignore received PIM join or IGMP report messages :ref Reference: protocols ip prefix-list * .. osdx:cfgcmd:: interfaces bridge vif ip ospf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Open Shortest Path First (OSPF) parameters .. osdx:cfgcmd:: interfaces bridge vif ip ospf authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 OSPF interface authentication .. osdx:cfgcmd:: interfaces bridge vif ip ospf authentication encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: Encrypted password .. osdx:cfgcmd:: interfaces bridge vif ip ospf authentication message-digest .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 authentication parameters :arg id: MD5 ID number (1-255) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif ip ospf authentication message-digest encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: MD5 encrypted key .. osdx:cfgcmd:: interfaces bridge vif ip ospf authentication message-digest password .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 key :arg txt: MD5 Key (1-16) .. osdx:cfgcmd:: interfaces bridge vif ip ospf authentication password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Plain text password .. osdx:cfgcmd:: interfaces bridge vif ip ospf bandwidth .. raw:: html SDE M10-Smart M2 RS420 AresC640 Bandwidth of interface (kilobits/sec) :arg u32: Bandwidth in kilobits/sec (for calculating OSPF cost) (1-10000000) .. osdx:cfgcmd:: interfaces bridge vif ip ospf cost .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interface cost :arg u32: OSPF interface cost (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ip ospf dead-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval after which neighbor is dead :arg u32: OSPF dead interval in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ip ospf hello-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between hello packets :arg u32: Interval between OSPF hello packets in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ip ospf mtu-ignore .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable Maximum Transmission Unit (MTU) mismatch detection .. osdx:cfgcmd:: interfaces bridge vif ip ospf network .. raw:: html SDE M10-Smart M2 RS420 AresC640 Network type :arg broadcast: Broadcast network type :arg non-broadcast: Non-broadcast network type :arg point-to-multipoint: Point-to-multipoint network type :arg point-to-point: Point-to-point network type .. osdx:cfgcmd:: interfaces bridge vif ip ospf priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Router priority :arg u32: Priority (0-255) .. osdx:cfgcmd:: interfaces bridge vif ip ospf retransmit-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between retransmitting lost link state advertisements :arg u32: Retransmit interval in seconds (3-65535) .. osdx:cfgcmd:: interfaces bridge vif ip ospf transmit-delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Link state transmit delay :arg u32: Transmit delay in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ip pim .. raw:: html SDE M10-Smart M2 RS420 AresC640 Protocol Independent Multicast (PIM) parameters .. osdx:cfgcmd:: interfaces bridge vif ip pim disable-bsm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable sending and receiving bootstrap messages .. osdx:cfgcmd:: interfaces bridge vif ip pim disable-unicast-bsm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable sending and receiving unicast bootstrap messages .. osdx:cfgcmd:: interfaces bridge vif ip pim drpriority .. raw:: html SDE M10-Smart M2 RS420 AresC640 PIM Designated Router (DR) priority :arg u32: PIM DR priority for the interface (1-4294967295) .. osdx:cfgcmd:: interfaces bridge vif ip pim hello .. raw:: html SDE M10-Smart M2 RS420 AresC640 PIM hello interval :arg u32: PIM hello interval in seconds (1-255) .. osdx:cfgcmd:: interfaces bridge vif ip pim passive .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable sending and receiving all PIM control messages (such as: ASSERT, BSM, HELLO, JOIN, PRUNE, REGISTER, REGISTER-STOP) .. osdx:cfgcmd:: interfaces bridge vif ip reverse-path-filter .. raw:: html SDE M10-Smart M2 RS420 AresC640 Policy for source validation by reversed path, as specified in RFC3704 :arg strict: Enable Strict Reverse Path Forwarding as defined in RFC3704 :arg loose: Enable Loose Reverse Path Forwarding as defined in RFC3704 :arg disable: No source validation .. osdx:cfgcmd:: interfaces bridge vif ip rip .. raw:: html SDE M10-Smart M2 RS420 AresC640 Routing Information Protocol (RIP) parameters .. osdx:cfgcmd:: interfaces bridge vif ip rip authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 Authentication method .. osdx:cfgcmd:: interfaces bridge vif ip rip authentication encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: Encrypted password .. osdx:cfgcmd:: interfaces bridge vif ip rip authentication message-digest .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 authentication parameters :arg u32: MD5 ID number (1-255) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif ip rip authentication message-digest encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: MD5 encrypted key .. osdx:cfgcmd:: interfaces bridge vif ip rip authentication message-digest password .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 key :arg txt: MD5 Key (1-16) .. osdx:cfgcmd:: interfaces bridge vif ip rip authentication password .. raw:: html SDE M10-Smart M2 RS420 AresC640 Plain text password :arg txt: Plain text password (1-16) .. osdx:cfgcmd:: interfaces bridge vif ip rip split-horizon .. raw:: html SDE M10-Smart M2 RS420 AresC640 Split horizon parameters .. osdx:cfgcmd:: interfaces bridge vif ip rip split-horizon disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable split horizon on specified interface .. osdx:cfgcmd:: interfaces bridge vif ip rip split-horizon poison-reverse .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable poison reverse for split-horizon .. osdx:cfgcmd:: interfaces bridge vif ipv6 .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 routing parameters .. osdx:cfgcmd:: interfaces bridge vif ipv6 address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 address auto-configuration modes .. osdx:cfgcmd:: interfaces bridge vif ipv6 address autoconf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable acquisition of IPv6 address using stateless autoconfig .. osdx:cfgcmd:: interfaces bridge vif ipv6 address eui64 .. raw:: html SDE M10-Smart M2 RS420 AresC640 Assign IPv6 address using EUI-64 based on MAC address :arg ipv6net: 64-bit IPv6 prefix to use with EUI-64 to make address :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif ipv6 address prefix-from-provider .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: IPv6 from Learned Prefix :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif ipv6 address prefix-from-provider ifc-ID .. raw:: html SDE M10-Smart M2 RS420 AresC640 Assign IPv6 address using Learned Prefixes :arg <: 64-bit IPv6 prefix (:h:h:h:h/64>) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif ipv6 dhcp-client-pd .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: Name of learned prefix from provider .. osdx:cfgcmd:: interfaces bridge vif ipv6 disable-forwarding .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable IPv6 forwarding on this interface only .. osdx:cfgcmd:: interfaces bridge vif ipv6 dup-addr-detect-transmits .. raw:: html SDE M10-Smart M2 RS420 AresC640 Number of NS messages to send while performing DAD :arg u32: Number of NS messages to send while performing DAD (0-2147483647) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 Open Shortest Path First (OSPFv3) parameters .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 area .. raw:: html SDE M10-Smart M2 RS420 AresC640 OSPFv3 Area :arg u32: OSPFv3 area in decimal notation (0-4294967295) :arg ipv4: OSPFv3 area in dotted decimal notation .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 OSPFv3 interface authentication :instances: Unique .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 authentication hmac-sha-256 .. raw:: html SDE M10-Smart M2 RS420 AresC640 HMAC-SHA-256 authentication parameters :arg u32: HMAC-SHA-256 key ID (1-65535) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 authentication hmac-sha-256 encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: HMAC-SHA-256 encrypted password .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 authentication hmac-sha-256 password .. raw:: html SDE M10-Smart M2 RS420 AresC640 HMAC-SHA-256 plain text password :arg txt: HMAC-SHA-256 plain text password (1-16) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 authentication md5 .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 authentication parameters :arg u32: MD5 key ID (1-65535) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 authentication md5 encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: MD5 encrypted password .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 authentication md5 password .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 plain text password :arg txt: MD5 plain text password (1-16) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 cost .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interface cost :arg u32: OSPFv3 cost (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 dead-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval after which neighbor is declared dead :arg u32: Neighbor dead interval in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 hello-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between hello packets :arg u32: Interval between OSPFv3 hello packets in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 ifmtu .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interface MTU :arg u32: Interface MTU value (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 instance-id .. raw:: html SDE M10-Smart M2 RS420 AresC640 Instance identifier :arg u32: Instance ID (0-255) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 mtu-ignore .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable Maximum Transmission Unit mismatch detection .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 network .. raw:: html SDE M10-Smart M2 RS420 AresC640 Network type :arg broadcast: Broadcast network type :arg point-to-point: Point-to-point network type .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 passive .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable forming of adjacency .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Router priority :arg u32: Priority (0-255) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 retransmit-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between retransmitting lost link state advertisements :arg u32: Retransmit interval in seconds (3-65535) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ospfv3 transmit-delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Link state transmit delay :arg u32: Link state transmit delay in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ripng .. raw:: html SDE M10-Smart M2 RS420 AresC640 Routing Information Protocol (RIPng) .. osdx:cfgcmd:: interfaces bridge vif ipv6 ripng split-horizon .. raw:: html SDE M10-Smart M2 RS420 AresC640 Split horizon parameters .. osdx:cfgcmd:: interfaces bridge vif ipv6 ripng split-horizon disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable split horizon .. osdx:cfgcmd:: interfaces bridge vif ipv6 ripng split-horizon poison-reverse .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable poison reverse for split-horizon .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert .. raw:: html SDE M10-Smart M2 RS420 AresC640 Configure parameters for sending Router Advertisements (RAs) .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert cur-hop-limit .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to be placed in the Current Hop Limit field in RAs :arg u32: Value to place in the Current Hop Limit field in RAs (0-255) .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert default-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to be placed in Router Lifetime field in RAs :arg u32: Value in seconds to be placed in Router Lifetime field in RAs (4-9000) :arg u32: This means "not a default router", in Router Lifetime field (0) .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert default-preference .. raw:: html SDE M10-Smart M2 RS420 AresC640 Default router preference :arg low: Default router is low preference :arg medium: Default router is medium preference :arg high: Default router is high preference .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert link-mtu .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value of link MTU to place in RAs :arg u32: Do not send MTU options in RAs (0) :arg u32: Value of link MTU to place in RAs (1280-2147483647) .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert managed-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Value for "managed address configuration" flag in RAs .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert max-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Maximum interval between unsolicited multicast RAs :arg u32: Maximum interval in seconds between unsolicited multicast RAs (4-1800) .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert min-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Minimum interval between unsolicited multicast RAs :arg u32: Minimum interval in seconds between unsolicited multicast RAs (3-1350) .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert name-server .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv6: IPv6 address of a Recursive DNS Server :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert other-config-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Value to be placed in the "other configuration" flag in RAs .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert prefix .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 prefix to be advertised in Router Advertisements (RAs) :arg ipv6net: IPv6 prefix to be advertized in Router Advertisements (RAs) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert prefix autonomous-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Whether prefix can be used for address auto-configuration .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert prefix on-link-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Flag that prefix can be used for on-link determination .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert prefix preferred-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain preferred :arg u32: Time in seconds that the prefix will remain preferred (0-2147483647) :arg infinity: Prefix will remain preferred forever .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert prefix valid-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain valid :arg u32: Time in seconds that the prefix will remain valid (0-2147483647) :arg infinity: Prefix will remain valid forever .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert reachable-time .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to be placed in "Reachable Time" field in RAs :arg u32: Reachable Time value in RAs (in milliseconds) (1-3600000) :arg u32: Reachable Time 0 (i.e., unspecified by this router) (0) .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert retrans-timer .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to place in "Retrans Timer" field in RAs. :arg u32: Value in milliseconds to place in "Retrans Timer" field in RAs (0-2147483647) .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert send-advert .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Enable/disable sending RAs .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert used-prefixes .. raw:: html SDE M10-Smart M2 RS420 AresC640 Delegate prefixes used on the interface .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert used-prefixes autonomous-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Whether prefix can be used for address auto-configuration .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert used-prefixes on-link-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Flag that prefix can be used for on-link determination .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert used-prefixes preferred-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain preferred :arg u32: Time in seconds that the prefix will remain preferred (0-2147483647) :arg infinity: Prefix will remain preferred forever .. osdx:cfgcmd:: interfaces bridge vif ipv6 router-advert used-prefixes valid-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain valid :arg u32: Time in seconds that the prefix will remain valid (0-2147483647) :arg infinity: Prefix will remain valid forever .. osdx:cfgcmd:: interfaces bridge vif mac .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg macaddr: Media Access Control (MAC) address :arg ifc: Media Access Control (MAC) address .. osdx:cfgcmd:: interfaces bridge vif tcp-mss .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Change tcp-mss value .. osdx:cfgcmd:: interfaces bridge vif traffic .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic processing options .. osdx:cfgcmd:: interfaces bridge vif traffic control .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic control for interface .. osdx:cfgcmd:: interfaces bridge vif traffic control in .. raw:: html SDE M10-Smart M2 RS420 AresC640 Ingress traffic control for interface :ref Reference: traffic control * .. osdx:cfgcmd:: interfaces bridge vif traffic control out .. raw:: html SDE M10-Smart M2 RS420 AresC640 Egress traffic control for interface :ref Reference: traffic control * .. osdx:cfgcmd:: interfaces bridge vif traffic nat .. raw:: html SDE M10-Smart M2 RS420 AresC640 Network Address Translation (NAT) parameters .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination .. raw:: html SDE M10-Smart M2 RS420 AresC640 Destination NAT settings .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule .. raw:: html SDE M10-Smart M2 RS420 AresC640 Rule number for NAT :arg u32: Number for this NAT rule (1-9999) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP address, subnet, range or redirect :arg ipv4: NAT to the specified IP address :arg ipv4net: NAT to the specified network address :arg ipv4range: NAT to the specified IP range :arg redirect: NAT to the interface address .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule description .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Rule description .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule log .. raw:: html SDE M10-Smart M2 RS420 AresC640 Log packets to which this rule has been applied .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule log level .. raw:: html SDE M10-Smart M2 RS420 AresC640 Loggin level :arg emerg: Emergency messages :arg alert: Urgent messages :arg crit: Critical messages :arg err: Error messages :arg warn: Warning messages :arg notice: Messages for further investigation :arg info: Informational messages :arg debug: Debug messages .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule log prefix .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Log message prefix text, up to 29 characters .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule network .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP prefix to use in translation (host part is kept) :arg ipv4net: NAT to the specified network address, host part of the address will remain unchanged .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule port .. raw:: html SDE M10-Smart M2 RS420 AresC640 NAT port :arg u32: Port to use in PAT (1-65535) :arg range: Port range (pool, for example, 1001-1005) .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule protocol .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: NAT transport protocol .. osdx:cfgcmd:: interfaces bridge vif traffic nat destination rule selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge vif traffic nat source .. raw:: html SDE M10-Smart M2 RS420 AresC640 Source NAT settings .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule .. raw:: html SDE M10-Smart M2 RS420 AresC640 Rule number for NAT :arg u32: Number for this NAT rule (1-9999) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP address, subnet, range or masquerade :arg ipv4: NAT to the specified IP address :arg ipv4net: NAT to the specified network address :arg ipv4range: NAT to the specified IP range :arg masquerade: NAT to the interface address .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule description .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Rule description .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule log .. raw:: html SDE M10-Smart M2 RS420 AresC640 Log packets to which this rule has been applied .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule log level .. raw:: html SDE M10-Smart M2 RS420 AresC640 Loggin level :arg emerg: Emergency messages :arg alert: Urgent messages :arg crit: Critical messages :arg err: Error messages :arg warn: Warning messages :arg notice: Messages for further investigation :arg info: Informational messages :arg debug: Debug messages .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule log prefix .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Log message prefix text, up to 29 characters .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule network .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP prefix to use in translation (host part is kept) :arg ipv4net: NAT to the specified network address, host part of the address will remain unchanged .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule port .. raw:: html SDE M10-Smart M2 RS420 AresC640 NAT port :arg u32: Port to use in PAT (1-65535) :arg range: Port range (pool, for example, 1001-1005) .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule protocol .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: NAT transport protocol .. osdx:cfgcmd:: interfaces bridge vif traffic nat source rule selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge vif traffic policy .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic policy rulesets for interface .. osdx:cfgcmd:: interfaces bridge vif traffic policy in .. raw:: html SDE M10-Smart M2 RS420 AresC640 Input traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif traffic policy in priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed before NAT :arg high: Second policy executed before NAT :arg low: First policy executed after NAT :arg very-low: Second policy executed after NAT .. osdx:cfgcmd:: interfaces bridge vif traffic policy local-in .. raw:: html SDE M10-Smart M2 RS420 AresC640 Local input traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif traffic policy local-in priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed :arg high: Second policy executed :arg low: Third policy executed :arg very-low: Fourth policy executed .. osdx:cfgcmd:: interfaces bridge vif traffic policy local-out .. raw:: html SDE M10-Smart M2 RS420 AresC640 Local output traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif traffic policy local-out priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed :arg high: Second policy executed :arg low: Third policy executed :arg very-low: Fourth policy executed .. osdx:cfgcmd:: interfaces bridge vif traffic policy out .. raw:: html SDE M10-Smart M2 RS420 AresC640 Output traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif traffic policy out priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed before NAT :arg high: Second policy executed before NAT :arg low: First policy executed after NAT :arg very-low: Second policy executed after NAT .. osdx:cfgcmd:: interfaces bridge vif traffic zone .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic zone associated with this interface :ref Reference: traffic zone * .. osdx:cfgcmd:: interfaces bridge vif vif-c .. raw:: html SDE M10-Smart M2 RS420 AresC640 QinQ TAG-C Virtual Local Area Network (VLAN) ID :arg u32: VLAN ID (1-4094) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP address :arg ipv6cidr: IPv6 address and prefix length :arg dhcpv6: Dynamic Host Configuration Protocol for IPv6 :arg ipv4cidr: IPv4 address and prefix length :arg dhcp: Dynamic Host Configuration Protocol :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c alarm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable or disable alarm according the link state .. osdx:cfgcmd:: interfaces bridge vif vif-c alarm down .. raw:: html SDE M10-Smart M2 RS420 AresC640 Alarm to be enabled if the link is down :ref Reference: system alarm * .. osdx:cfgcmd:: interfaces bridge vif vif-c description .. raw:: html SDE M10-Smart M2 RS420 AresC640 Description :arg id: "Interface description is too long (limit 256 characters)" (1-256) .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Dynamic Host Configuration Protocol configuration .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client .. raw:: html SDE M10-Smart M2 RS420 AresC640 DHCP client configuration .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client fallback .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv4cidr: Fallback IP address :arg ipv6cidr: Fallback IP address .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client rfc3442-routes .. raw:: html SDE M10-Smart M2 RS420 AresC640 Install RFC3442 routes received from DHCP server .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client send .. raw:: html SDE M10-Smart M2 RS420 AresC640 Send user-defined options to the DHCP server .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client send dhcp-client-identifier .. raw:: html SDE M10-Smart M2 RS420 AresC640 Include the 'dhcp-client-identifier' option :instances: Unique .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client send dhcp-client-identifier base-mac .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use device base mac as identifier .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client send dhcp-client-identifier serial-number .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use device serial number as identifier .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client send dhcp-client-identifier string .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use a string as identifier :arg id: Identifier string (1-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client send vendor-class-identifier .. raw:: html SDE M10-Smart M2 RS420 AresC640 Include the 'vendor-class-identifier' option :instances: Unique .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcp client send vendor-class-identifier string .. raw:: html SDE M10-Smart M2 RS420 AresC640 Use a string as identifier :arg id: Identifier string (1-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcpv6 .. raw:: html SDE M10-Smart M2 RS420 AresC640 Dynamic Host Configuration Protocol v6 configuration .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcpv6 client .. raw:: html SDE M10-Smart M2 RS420 AresC640 DHCPv6 client configuration .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcpv6 client parameters-only .. raw:: html SDE M10-Smart M2 RS420 AresC640 Acquire only config parameters, not address .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcpv6 client send .. raw:: html SDE M10-Smart M2 RS420 AresC640 Send user-defined options to the DHCPv6 server .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcpv6 client send duid .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: DHCPv6 DUID to be sent by dhcpv6 client .. osdx:cfgcmd:: interfaces bridge vif vif-c dhcpv6 client temporary .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 "temporary" address .. osdx:cfgcmd:: interfaces bridge vif vif-c disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable interface .. osdx:cfgcmd:: interfaces bridge vif vif-c disable advisor .. raw:: html SDE M10-Smart M2 RS420 AresC640 Advisor to enable or disable the interface :ref Reference: system advisor * .. osdx:cfgcmd:: interfaces bridge vif vif-c flow .. raw:: html SDE M10-Smart M2 RS420 AresC640 Active netflow on interface .. osdx:cfgcmd:: interfaces bridge vif vif-c flow egress .. raw:: html SDE M10-Smart M2 RS420 AresC640 Active output traffic .. osdx:cfgcmd:: interfaces bridge vif vif-c flow egress selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge vif vif-c flow ingress .. raw:: html SDE M10-Smart M2 RS420 AresC640 Active input traffic .. osdx:cfgcmd:: interfaces bridge vif vif-c flow ingress selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge vif vif-c ip .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv4 routing parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ip arp .. raw:: html SDE M10-Smart M2 RS420 AresC640 ARP options .. osdx:cfgcmd:: interfaces bridge vif vif-c ip arp ignore .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable arp-ignore on this interface .. osdx:cfgcmd:: interfaces bridge vif vif-c ip arp no-filter .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable arp-filter on this interface .. osdx:cfgcmd:: interfaces bridge vif vif-c ip arp no-notify .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable arp_notify on this interface .. osdx:cfgcmd:: interfaces bridge vif vif-c ip arp proxy .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable proxy-arp on this interface .. osdx:cfgcmd:: interfaces bridge vif vif-c ip arp pvlan-proxy .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable private VLAN proxy ARP on this interface .. osdx:cfgcmd:: interfaces bridge vif vif-c ip arp static .. raw:: html SDE M10-Smart M2 RS420 AresC640 Static ARP translation :arg ipv4: IPv4 address to add in ARP table :instances: Multiple :ref Required: .. osdx:cfgcmd:: interfaces bridge vif vif-c ip arp static mac .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg macaddr: MAC address .. osdx:cfgcmd:: interfaces bridge vif vif-c ip arp timeout .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: ARP cache entry timeout in seconds .. osdx:cfgcmd:: interfaces bridge vif vif-c ip igmp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Internet Group Management Protocol (IGMP) parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ip igmp join .. raw:: html SDE M10-Smart M2 RS420 AresC640 Join multicast group :arg ipv4: Join multicast group on this interface .. osdx:cfgcmd:: interfaces bridge vif vif-c ip igmp last-member-query-count .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP last member query count :arg u32: IGMP last member query count (1-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip igmp last-member-query-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP last member query interval :arg u32: IGMP last member query interval in deciseconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip igmp query-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP query interval :arg u32: IGMP query interval in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip igmp query-max-response-time .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP query response timeout value :arg u32: IGMP query response timeout value in deciseconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip igmp version .. raw:: html SDE M10-Smart M2 RS420 AresC640 IGMP version :arg u32: IGMP version used on this interface (2-3) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip multicast .. raw:: html SDE M10-Smart M2 RS420 AresC640 Multicast parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ip multicast boundary-list .. raw:: html SDE M10-Smart M2 RS420 AresC640 Prefix-list to control for which groups to accept or ignore received PIM join or IGMP report messages :ref Reference: protocols ip prefix-list * .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Open Shortest Path First (OSPF) parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 OSPF interface authentication .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf authentication encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: Encrypted password .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf authentication message-digest .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 authentication parameters :arg id: MD5 ID number (1-255) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf authentication message-digest encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: MD5 encrypted key .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf authentication message-digest password .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 key :arg txt: MD5 Key (1-16) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf authentication password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Plain text password .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf bandwidth .. raw:: html SDE M10-Smart M2 RS420 AresC640 Bandwidth of interface (kilobits/sec) :arg u32: Bandwidth in kilobits/sec (for calculating OSPF cost) (1-10000000) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf cost .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interface cost :arg u32: OSPF interface cost (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf dead-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval after which neighbor is dead :arg u32: OSPF dead interval in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf hello-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between hello packets :arg u32: Interval between OSPF hello packets in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf mtu-ignore .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable Maximum Transmission Unit (MTU) mismatch detection .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf network .. raw:: html SDE M10-Smart M2 RS420 AresC640 Network type :arg broadcast: Broadcast network type :arg non-broadcast: Non-broadcast network type :arg point-to-multipoint: Point-to-multipoint network type :arg point-to-point: Point-to-point network type .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Router priority :arg u32: Priority (0-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf retransmit-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between retransmitting lost link state advertisements :arg u32: Retransmit interval in seconds (3-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip ospf transmit-delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Link state transmit delay :arg u32: Transmit delay in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip pim .. raw:: html SDE M10-Smart M2 RS420 AresC640 Protocol Independent Multicast (PIM) parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ip pim disable-bsm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable sending and receiving bootstrap messages .. osdx:cfgcmd:: interfaces bridge vif vif-c ip pim disable-unicast-bsm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable sending and receiving unicast bootstrap messages .. osdx:cfgcmd:: interfaces bridge vif vif-c ip pim drpriority .. raw:: html SDE M10-Smart M2 RS420 AresC640 PIM Designated Router (DR) priority :arg u32: PIM DR priority for the interface (1-4294967295) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip pim hello .. raw:: html SDE M10-Smart M2 RS420 AresC640 PIM hello interval :arg u32: PIM hello interval in seconds (1-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip pim passive .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable sending and receiving all PIM control messages (such as: ASSERT, BSM, HELLO, JOIN, PRUNE, REGISTER, REGISTER-STOP) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip reverse-path-filter .. raw:: html SDE M10-Smart M2 RS420 AresC640 Policy for source validation by reversed path, as specified in RFC3704 :arg strict: Enable Strict Reverse Path Forwarding as defined in RFC3704 :arg loose: Enable Loose Reverse Path Forwarding as defined in RFC3704 :arg disable: No source validation .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip .. raw:: html SDE M10-Smart M2 RS420 AresC640 Routing Information Protocol (RIP) parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 Authentication method .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip authentication encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: Encrypted password .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip authentication message-digest .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 authentication parameters :arg u32: MD5 ID number (1-255) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip authentication message-digest encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: MD5 encrypted key .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip authentication message-digest password .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 key :arg txt: MD5 Key (1-16) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip authentication password .. raw:: html SDE M10-Smart M2 RS420 AresC640 Plain text password :arg txt: Plain text password (1-16) .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip split-horizon .. raw:: html SDE M10-Smart M2 RS420 AresC640 Split horizon parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip split-horizon disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable split horizon on specified interface .. osdx:cfgcmd:: interfaces bridge vif vif-c ip rip split-horizon poison-reverse .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable poison reverse for split-horizon .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 routing parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 address auto-configuration modes .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 address autoconf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable acquisition of IPv6 address using stateless autoconfig .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 address eui64 .. raw:: html SDE M10-Smart M2 RS420 AresC640 Assign IPv6 address using EUI-64 based on MAC address :arg ipv6net: 64-bit IPv6 prefix to use with EUI-64 to make address :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 address prefix-from-provider .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: IPv6 from Learned Prefix :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 address prefix-from-provider ifc-ID .. raw:: html SDE M10-Smart M2 RS420 AresC640 Assign IPv6 address using Learned Prefixes :arg <: 64-bit IPv6 prefix (:h:h:h:h/64>) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 dhcp-client-pd .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: Name of learned prefix from provider .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 disable-forwarding .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable IPv6 forwarding on this interface only .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 dup-addr-detect-transmits .. raw:: html SDE M10-Smart M2 RS420 AresC640 Number of NS messages to send while performing DAD :arg u32: Number of NS messages to send while performing DAD (0-2147483647) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 Open Shortest Path First (OSPFv3) parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 area .. raw:: html SDE M10-Smart M2 RS420 AresC640 OSPFv3 Area :arg u32: OSPFv3 area in decimal notation (0-4294967295) :arg ipv4: OSPFv3 area in dotted decimal notation .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 OSPFv3 interface authentication :instances: Unique .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 authentication hmac-sha-256 .. raw:: html SDE M10-Smart M2 RS420 AresC640 HMAC-SHA-256 authentication parameters :arg u32: HMAC-SHA-256 key ID (1-65535) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 authentication hmac-sha-256 encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: HMAC-SHA-256 encrypted password .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 authentication hmac-sha-256 password .. raw:: html SDE M10-Smart M2 RS420 AresC640 HMAC-SHA-256 plain text password :arg txt: HMAC-SHA-256 plain text password (1-16) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 authentication md5 .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 authentication parameters :arg u32: MD5 key ID (1-65535) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 authentication md5 encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: MD5 encrypted password .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 authentication md5 password .. raw:: html SDE M10-Smart M2 RS420 AresC640 MD5 plain text password :arg txt: MD5 plain text password (1-16) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 cost .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interface cost :arg u32: OSPFv3 cost (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 dead-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval after which neighbor is declared dead :arg u32: Neighbor dead interval in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 hello-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between hello packets :arg u32: Interval between OSPFv3 hello packets in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 ifmtu .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interface MTU :arg u32: Interface MTU value (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 instance-id .. raw:: html SDE M10-Smart M2 RS420 AresC640 Instance identifier :arg u32: Instance ID (0-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 mtu-ignore .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable Maximum Transmission Unit mismatch detection .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 network .. raw:: html SDE M10-Smart M2 RS420 AresC640 Network type :arg broadcast: Broadcast network type :arg point-to-point: Point-to-point network type .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 passive .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable forming of adjacency .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Router priority :arg u32: Priority (0-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 retransmit-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Interval between retransmitting lost link state advertisements :arg u32: Retransmit interval in seconds (3-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ospfv3 transmit-delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Link state transmit delay :arg u32: Link state transmit delay in seconds (1-65535) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ripng .. raw:: html SDE M10-Smart M2 RS420 AresC640 Routing Information Protocol (RIPng) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ripng split-horizon .. raw:: html SDE M10-Smart M2 RS420 AresC640 Split horizon parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ripng split-horizon disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 Disable split horizon .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 ripng split-horizon poison-reverse .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable poison reverse for split-horizon .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert .. raw:: html SDE M10-Smart M2 RS420 AresC640 Configure parameters for sending Router Advertisements (RAs) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert cur-hop-limit .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to be placed in the Current Hop Limit field in RAs :arg u32: Value to place in the Current Hop Limit field in RAs (0-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert default-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to be placed in Router Lifetime field in RAs :arg u32: Value in seconds to be placed in Router Lifetime field in RAs (4-9000) :arg u32: This means "not a default router", in Router Lifetime field (0) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert default-preference .. raw:: html SDE M10-Smart M2 RS420 AresC640 Default router preference :arg low: Default router is low preference :arg medium: Default router is medium preference :arg high: Default router is high preference .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert link-mtu .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value of link MTU to place in RAs :arg u32: Do not send MTU options in RAs (0) :arg u32: Value of link MTU to place in RAs (1280-2147483647) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert managed-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Value for "managed address configuration" flag in RAs .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert max-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Maximum interval between unsolicited multicast RAs :arg u32: Maximum interval in seconds between unsolicited multicast RAs (4-1800) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert min-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Minimum interval between unsolicited multicast RAs :arg u32: Minimum interval in seconds between unsolicited multicast RAs (3-1350) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert name-server .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv6: IPv6 address of a Recursive DNS Server :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert other-config-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Value to be placed in the "other configuration" flag in RAs .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert prefix .. raw:: html SDE M10-Smart M2 RS420 AresC640 IPv6 prefix to be advertised in Router Advertisements (RAs) :arg ipv6net: IPv6 prefix to be advertized in Router Advertisements (RAs) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert prefix autonomous-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Whether prefix can be used for address auto-configuration .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert prefix on-link-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Flag that prefix can be used for on-link determination .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert prefix preferred-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain preferred :arg u32: Time in seconds that the prefix will remain preferred (0-2147483647) :arg infinity: Prefix will remain preferred forever .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert prefix valid-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain valid :arg u32: Time in seconds that the prefix will remain valid (0-2147483647) :arg infinity: Prefix will remain valid forever .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert reachable-time .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to be placed in "Reachable Time" field in RAs :arg u32: Reachable Time value in RAs (in milliseconds) (1-3600000) :arg u32: Reachable Time 0 (i.e., unspecified by this router) (0) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert retrans-timer .. raw:: html SDE M10-Smart M2 RS420 AresC640 Value to place in "Retrans Timer" field in RAs. :arg u32: Value in milliseconds to place in "Retrans Timer" field in RAs (0-2147483647) .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert send-advert .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Enable/disable sending RAs .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert used-prefixes .. raw:: html SDE M10-Smart M2 RS420 AresC640 Delegate prefixes used on the interface .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert used-prefixes autonomous-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Whether prefix can be used for address auto-configuration .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert used-prefixes on-link-flag .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Flag that prefix can be used for on-link determination .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert used-prefixes preferred-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain preferred :arg u32: Time in seconds that the prefix will remain preferred (0-2147483647) :arg infinity: Prefix will remain preferred forever .. osdx:cfgcmd:: interfaces bridge vif vif-c ipv6 router-advert used-prefixes valid-lifetime .. raw:: html SDE M10-Smart M2 RS420 AresC640 Time in seconds that the prefix will remain valid :arg u32: Time in seconds that the prefix will remain valid (0-2147483647) :arg infinity: Prefix will remain valid forever .. osdx:cfgcmd:: interfaces bridge vif vif-c mac .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg macaddr: Media Access Control (MAC) address :arg ifc: Media Access Control (MAC) address .. osdx:cfgcmd:: interfaces bridge vif vif-c tcp-mss .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Change tcp-mss value .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic processing options .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic control .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic control for interface .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic control in .. raw:: html SDE M10-Smart M2 RS420 AresC640 Ingress traffic control for interface :ref Reference: traffic control * .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic control out .. raw:: html SDE M10-Smart M2 RS420 AresC640 Egress traffic control for interface :ref Reference: traffic control * .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat .. raw:: html SDE M10-Smart M2 RS420 AresC640 Network Address Translation (NAT) parameters .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination .. raw:: html SDE M10-Smart M2 RS420 AresC640 Destination NAT settings .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule .. raw:: html SDE M10-Smart M2 RS420 AresC640 Rule number for NAT :arg u32: Number for this NAT rule (1-9999) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP address, subnet, range or redirect :arg ipv4: NAT to the specified IP address :arg ipv4net: NAT to the specified network address :arg ipv4range: NAT to the specified IP range :arg redirect: NAT to the interface address .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule description .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Rule description .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule log .. raw:: html SDE M10-Smart M2 RS420 AresC640 Log packets to which this rule has been applied .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule log level .. raw:: html SDE M10-Smart M2 RS420 AresC640 Loggin level :arg emerg: Emergency messages :arg alert: Urgent messages :arg crit: Critical messages :arg err: Error messages :arg warn: Warning messages :arg notice: Messages for further investigation :arg info: Informational messages :arg debug: Debug messages .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule log prefix .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Log message prefix text, up to 29 characters .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule network .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP prefix to use in translation (host part is kept) :arg ipv4net: NAT to the specified network address, host part of the address will remain unchanged .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule port .. raw:: html SDE M10-Smart M2 RS420 AresC640 NAT port :arg u32: Port to use in PAT (1-65535) :arg range: Port range (pool, for example, 1001-1005) .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule protocol .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: NAT transport protocol .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat destination rule selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source .. raw:: html SDE M10-Smart M2 RS420 AresC640 Source NAT settings .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule .. raw:: html SDE M10-Smart M2 RS420 AresC640 Rule number for NAT :arg u32: Number for this NAT rule (1-9999) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule address .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP address, subnet, range or masquerade :arg ipv4: NAT to the specified IP address :arg ipv4net: NAT to the specified network address :arg ipv4range: NAT to the specified IP range :arg masquerade: NAT to the interface address .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule description .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Rule description .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule log .. raw:: html SDE M10-Smart M2 RS420 AresC640 Log packets to which this rule has been applied .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule log level .. raw:: html SDE M10-Smart M2 RS420 AresC640 Loggin level :arg emerg: Emergency messages :arg alert: Urgent messages :arg crit: Critical messages :arg err: Error messages :arg warn: Warning messages :arg notice: Messages for further investigation :arg info: Informational messages :arg debug: Debug messages .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule log prefix .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Log message prefix text, up to 29 characters .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule network .. raw:: html SDE M10-Smart M2 RS420 AresC640 IP prefix to use in translation (host part is kept) :arg ipv4net: NAT to the specified network address, host part of the address will remain unchanged .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule port .. raw:: html SDE M10-Smart M2 RS420 AresC640 NAT port :arg u32: Port to use in PAT (1-65535) :arg range: Port range (pool, for example, 1001-1005) .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule protocol .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: NAT transport protocol .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic nat source rule selector .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic selector :ref Reference: traffic selector * .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic policy .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic policy rulesets for interface .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic policy in .. raw:: html SDE M10-Smart M2 RS420 AresC640 Input traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic policy in priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed before NAT :arg high: Second policy executed before NAT :arg low: First policy executed after NAT :arg very-low: Second policy executed after NAT .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic policy local-in .. raw:: html SDE M10-Smart M2 RS420 AresC640 Local input traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic policy local-in priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed :arg high: Second policy executed :arg low: Third policy executed :arg very-low: Fourth policy executed .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic policy local-out .. raw:: html SDE M10-Smart M2 RS420 AresC640 Local output traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic policy local-out priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed :arg high: Second policy executed :arg low: Third policy executed :arg very-low: Fourth policy executed .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic policy out .. raw:: html SDE M10-Smart M2 RS420 AresC640 Output traffic policy ruleset for interface :ref Reference: traffic policy * :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic policy out priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority order for traffic policy :arg very-high: First policy executed before NAT :arg high: Second policy executed before NAT :arg low: First policy executed after NAT :arg very-low: Second policy executed after NAT .. osdx:cfgcmd:: interfaces bridge vif vif-c traffic zone .. raw:: html SDE M10-Smart M2 RS420 AresC640 Traffic zone associated with this interface :ref Reference: traffic zone * .. osdx:cfgcmd:: interfaces bridge vif vif-c vrf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual Routing and Forwarding domain name :ref Reference: system vrf * .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual Router Redundancy Protocol (VRRP) .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group .. raw:: html SDE M10-Smart M2 RS420 AresC640 VRRP group number :arg u32: VRRP group number (1-255) :instances: Multiple :ref Required: .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group advertise-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Advertise interval :arg u32: Advertise interval (1-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group advisor .. raw:: html SDE M10-Smart M2 RS420 AresC640 Check advisor :ref Reference: system advisor * .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group alarm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Sets alarm on vrrp state change :ref Reference: system alarm * .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 Authentication :ref Required: :ref Required: .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group authentication encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: Encrypted password .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group authentication password .. raw:: html SDE M10-Smart M2 RS420 AresC640 Plain text password :arg txt: Plain text password (1-8) .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group authentication type .. raw:: html SDE M10-Smart M2 RS420 AresC640 Authentication type :arg plaintext-password: Plain text password mode :arg ah: IP Authentication Header mode .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group description .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Description .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 VRRP group disabled .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group preempt .. raw:: html SDE M10-Smart M2 RS420 AresC640 Preempt mode .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group preempt delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Preempt delay :arg u32: Preempt Delay in seconds (0-1000) .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority :arg u32: Priority (1-255) .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group rfc3768-compatibility .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable RFC 3768 compatibility .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group source-address .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv4: Source address for vrrp packets .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group sync-group .. raw:: html SDE M10-Smart M2 RS420 AresC640 Add this vrrp group to a sync group :ref Reference: system vrrp sync-group * .. osdx:cfgcmd:: interfaces bridge vif vif-c vrrp vrrp-group virtual-address .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual address :arg ipv4: Virtual IP address (up to 20 per group) :arg ipv4net: Virtual IP address with prefix (up to 20 per group) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vif vrf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual Routing and Forwarding domain name :ref Reference: system vrf * .. osdx:cfgcmd:: interfaces bridge vif vrrp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual Router Redundancy Protocol (VRRP) .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group .. raw:: html SDE M10-Smart M2 RS420 AresC640 VRRP group number :arg u32: VRRP group number (1-255) :instances: Multiple :ref Required: .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group advertise-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Advertise interval :arg u32: Advertise interval (1-255) .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group advisor .. raw:: html SDE M10-Smart M2 RS420 AresC640 Check advisor :ref Reference: system advisor * .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group alarm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Sets alarm on vrrp state change :ref Reference: system alarm * .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 Authentication :ref Required: :ref Required: .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group authentication encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: Encrypted password .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group authentication password .. raw:: html SDE M10-Smart M2 RS420 AresC640 Plain text password :arg txt: Plain text password (1-8) .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group authentication type .. raw:: html SDE M10-Smart M2 RS420 AresC640 Authentication type :arg plaintext-password: Plain text password mode :arg ah: IP Authentication Header mode .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group description .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Description .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 VRRP group disabled .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group preempt .. raw:: html SDE M10-Smart M2 RS420 AresC640 Preempt mode .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group preempt delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Preempt delay :arg u32: Preempt Delay in seconds (0-1000) .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority :arg u32: Priority (1-255) .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group rfc3768-compatibility .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable RFC 3768 compatibility .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group source-address .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv4: Source address for vrrp packets .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group sync-group .. raw:: html SDE M10-Smart M2 RS420 AresC640 Add this vrrp group to a sync group :ref Reference: system vrrp sync-group * .. osdx:cfgcmd:: interfaces bridge vif vrrp vrrp-group virtual-address .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual address :arg ipv4: Virtual IP address (up to 20 per group) :arg ipv4net: Virtual IP address with prefix (up to 20 per group) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vlan .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable VLAN in master bridge interface :arg u32: VLAN ID (1-4094) :instances: Multiple .. osdx:cfgcmd:: interfaces bridge vlan pvid .. raw:: html SDE M10-Smart M2 RS420 AresC640 This VLAN specified is to be considered a PVID at ingress Any untagged frames will be assigned to this VLAN .. osdx:cfgcmd:: interfaces bridge vlan untagged .. raw:: html SDE M10-Smart M2 RS420 AresC640 This VLAN is to be treated as untagged on egress The bridge will always remove the VLAN tag from egress packets .. osdx:cfgcmd:: interfaces bridge vrf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual Routing and Forwarding domain name :ref Reference: system vrf * .. osdx:cfgcmd:: interfaces bridge vrrp .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual Router Redundancy Protocol (VRRP) .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group .. raw:: html SDE M10-Smart M2 RS420 AresC640 VRRP group number :arg u32: VRRP group number (1-255) :instances: Multiple :ref Required: .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group advertise-interval .. raw:: html SDE M10-Smart M2 RS420 AresC640 Advertise interval :arg u32: Advertise interval (1-255) .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group advisor .. raw:: html SDE M10-Smart M2 RS420 AresC640 Check advisor :ref Reference: system advisor * .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group alarm .. raw:: html SDE M10-Smart M2 RS420 AresC640 Sets alarm on vrrp state change :ref Reference: system alarm * .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group authentication .. raw:: html SDE M10-Smart M2 RS420 AresC640 Authentication :ref Required: :ref Required: .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group authentication encrypted-password .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg password: Encrypted password .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group authentication password .. raw:: html SDE M10-Smart M2 RS420 AresC640 Plain text password :arg txt: Plain text password (1-8) .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group authentication type .. raw:: html SDE M10-Smart M2 RS420 AresC640 Authentication type :arg plaintext-password: Plain text password mode :arg ah: IP Authentication Header mode .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group description .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Description .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group disable .. raw:: html SDE M10-Smart M2 RS420 AresC640 VRRP group disabled .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group preempt .. raw:: html SDE M10-Smart M2 RS420 AresC640 Preempt mode .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group preempt delay .. raw:: html SDE M10-Smart M2 RS420 AresC640 Preempt delay :arg u32: Preempt Delay in seconds (0-1000) .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group priority .. raw:: html SDE M10-Smart M2 RS420 AresC640 Priority :arg u32: Priority (1-255) .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group rfc3768-compatibility .. raw:: html SDE M10-Smart M2 RS420 AresC640 Enable RFC 3768 compatibility .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group source-address .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv4: Source address for vrrp packets .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group sync-group .. raw:: html SDE M10-Smart M2 RS420 AresC640 Add this vrrp group to a sync group :ref Reference: system vrrp sync-group * .. osdx:cfgcmd:: interfaces bridge vrrp vrrp-group virtual-address .. raw:: html SDE M10-Smart M2 RS420 AresC640 Virtual address :arg ipv4: Virtual IP address (up to 20 per group) :arg ipv4net: Virtual IP address with prefix (up to 20 per group) :instances: Multiple