netflow ------- .. osdx:cfgcmd:: system netflow .. raw:: html SDE M10-Smart M2 RS420 AresC640 Flow accounting settings :ref Required: .. osdx:cfgcmd:: system netflow app-id .. raw:: html SDE M10-Smart M2 RS420 AresC640 Collect and export app-id .. osdx:cfgcmd:: system netflow connmark .. raw:: html SDE M10-Smart M2 RS420 AresC640 Connmark configuration and collect and export connmark .. osdx:cfgcmd:: system netflow connmark mark .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Choose a mark to identify connmark :instances: Multiple .. osdx:cfgcmd:: system netflow connmark mark name .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Name of connmark-tag .. osdx:cfgcmd:: system netflow connmark vrf-mark .. raw:: html SDE M10-Smart M2 RS420 AresC640 Choose a vrf mark to identify connmark :ref Reference: system vrf * :instances: Multiple .. osdx:cfgcmd:: system netflow connmark vrf-mark name .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg txt: Name of connmark-tag .. osdx:cfgcmd:: system netflow debug .. raw:: html SDE M10-Smart M2 RS420 AresC640 Debug verbosity level :arg u32: Level (0-4) .. osdx:cfgcmd:: system netflow destination .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg fqdn: Export destination domain name :arg ipv4: Export destination domain name :arg ipv6: Export destination domain name :instances: Multiple .. osdx:cfgcmd:: system netflow destination dont-verify-server .. raw:: html SDE M10-Smart M2 RS420 AresC640 Dont check authentity of server certificates .. osdx:cfgcmd:: system netflow destination dtls .. raw:: html SDE M10-Smart M2 RS420 AresC640 Encrypt netflow traffic .. osdx:cfgcmd:: system netflow destination port .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Destination port .. osdx:cfgcmd:: system netflow dns-host .. raw:: html SDE M10-Smart M2 RS420 AresC640 Collect and export dns host .. osdx:cfgcmd:: system netflow engine-id .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Observation Domain ID .. osdx:cfgcmd:: system netflow exportcpu .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Lock exporter to this cpu .. osdx:cfgcmd:: system netflow hashsize .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Hash table size .. osdx:cfgcmd:: system netflow http-host .. raw:: html SDE M10-Smart M2 RS420 AresC640 Collect and export http host .. osdx:cfgcmd:: system netflow http-ref .. raw:: html SDE M10-Smart M2 RS420 AresC640 Collect and export http referer .. osdx:cfgcmd:: system netflow http-ua .. raw:: html SDE M10-Smart M2 RS420 AresC640 Collect and export http user agent .. osdx:cfgcmd:: system netflow http-url .. raw:: html SDE M10-Smart M2 RS420 AresC640 Collect and export http url .. osdx:cfgcmd:: system netflow local-address .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ipv4: Choose the output local address :arg ipv6: Choose the output local address :Local IP address: .. osdx:cfgcmd:: system netflow local-interface .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg ifc: Choose the output local interface .. osdx:cfgcmd:: system netflow local-vrf .. raw:: html SDE M10-Smart M2 RS420 AresC640 Choose the output local vrf :ref Reference: system vrf * .. osdx:cfgcmd:: system netflow mark .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Choose a number to mark netflow traffic .. osdx:cfgcmd:: system netflow maxflows .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Maximum number of flows .. osdx:cfgcmd:: system netflow protocol .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: Netflow protocol version .. osdx:cfgcmd:: system netflow refresh-rate .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: NetFlow v9/IPFIX refresh rate (packets) .. osdx:cfgcmd:: system netflow send-buffer .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Udp socket SNDBUF size (in bytes) .. osdx:cfgcmd:: system netflow ssl-server .. raw:: html SDE M10-Smart M2 RS420 AresC640 Collect and export ssl server name identifier .. osdx:cfgcmd:: system netflow timeout .. raw:: html SDE M10-Smart M2 RS420 AresC640 Netflow timeouts .. osdx:cfgcmd:: system netflow timeout active .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Active flows timeout in seconds .. osdx:cfgcmd:: system netflow timeout inactive .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: Inactive flows timeout in seconds .. osdx:cfgcmd:: system netflow timeout rate .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg u32: NetFlow v9/IPFIX timeout rate (minutes) .. osdx:cfgcmd:: system netflow vrf-mark .. raw:: html SDE M10-Smart M2 RS420 AresC640 Choose a vrf to mark netflow traffic :ref Reference: system vrf * :instances: Multiple .. osdx:cfgcmd:: system netflow vrf-mark name .. raw:: html SDE M10-Smart M2 RS420 AresC640 :arg id: Name of mark-tag