Rtc
This scenario shows how to configure NTP client/server authentication.
Test RTC Synchronization
Description
Checks that RTC is working properly on machines that have an RTC device.
Scenario
Step 1: Set the following configuration in DUT1
:
set interfaces ethernet eth0 address 10.100.0.100/24 set protocols static route 0.0.0.0/0 next-hop 10.100.0.50 set system ntp master prefer set system ntp master stratum 3
Step 2: Set the following configuration in DUT0
:
set interfaces ethernet eth0 address 10.100.0.50/24
Step 3: Ping IP address 10.100.0.100
from DUT0
:
admin@DUT0$ ping 10.100.0.100 count 1 size 56 timeout 1Show output
PING 10.100.0.100 (10.100.0.100) 56(84) bytes of data. 64 bytes from 10.100.0.100: icmp_seq=1 ttl=64 time=4.45 ms --- 10.100.0.100 ping statistics --- 1 packets transmitted, 1 received, 0% packet loss, time 0ms rtt min/avg/max/mdev = 4.445/4.445/4.445/0.000 ms
Step 4: Run command set date 2024-06-23 12:00:00
at DUT0
and expect this output:
Step 5: Run command set date ntp 10.100.0.100
at DUT0
and check if output does not contain the following tokens:
skipping this serverShow output
Date was successfully updated!
Step 6: Run command show date
at DUT0
and check if output does not contain the following tokens:
Sun
Show output
Mon 24 Jun 2024 11:46:26 UTC +00:00
Step 7: Run command set date hwclock from-system debug
at DUT0
and expect this output:
Show output
hwclock from util-linux 2.33.1 System Time: 1719229586.692948 Trying to open: /dev/rtc0 Using the rtc interface to the clock. Last drift adjustment done at 1719229585 seconds after 1969 Last calibration done at 1719229585 seconds after 1969 Hardware clock is on UTC time Assuming hardware clock is kept in UTC time. RTC type: 'rtc_cmos' Using delay: 0.500000 seconds missed it - 1719229586.693909 is too far past 1719229586.500000 (0.193909 > 0.001000) 1719229587.500000 is close enough to 1719229587.500000 (0.000000 < 0.002000) Set RTC to 1719229587 (1719229586 + 1; refsystime = 1719229586.000000) Setting Hardware Clock to 11:46:27 = 1719229587 seconds since 1969 ioctl(RTC_SET_TIME) was successful. Not adjusting drift factor because the --update-drift option was not used. New /etc/adjtime data: 0.000000 1719229586 0.000000 1719229586 UTC
Step 8: Run command set date hwclock to-system debug
at DUT0
and expect this output:
Show output
hwclock from util-linux 2.33.1 System Time: 1719229587.607587 Trying to open: /dev/rtc0 Using the rtc interface to the clock. Last drift adjustment done at 1719229586 seconds after 1969 Last calibration done at 1719229586 seconds after 1969 Hardware clock is on UTC time Assuming hardware clock is kept in UTC time. Waiting for clock tick... ...got clock tick Time read from Hardware Clock: 2024/06/24 11:46:28 Hw clock time : 2024/06/24 11:46:28 = 1719229588 seconds since 1969 Time since last adjustment is 2 seconds Calculated Hardware Clock drift is 0.000000 seconds Calling settimeofday(1719229588.000000, 0)
Step 9: Run command show date
at DUT0
and check if output does not contain the following tokens:
Sun
Show output
Mon 24 Jun 2024 11:46:28 UTC +00:00
Test RTC Synchronization With Drift
Description
Tests that RTC is working properly on machines that have an RTC device (while adjusting the drift too).
Scenario
Step 1: Set the following configuration in DUT1
:
set interfaces ethernet eth0 address 10.100.0.100/24 set protocols static route 0.0.0.0/0 next-hop 10.100.0.50 set system ntp master prefer set system ntp master stratum 3
Step 2: Set the following configuration in DUT0
:
set interfaces ethernet eth0 address 10.100.0.50/24
Step 3: Ping IP address 10.100.0.100
from DUT0
:
admin@DUT0$ ping 10.100.0.100 count 1 size 56 timeout 1Show output
PING 10.100.0.100 (10.100.0.100) 56(84) bytes of data. 64 bytes from 10.100.0.100: icmp_seq=1 ttl=64 time=0.496 ms --- 10.100.0.100 ping statistics --- 1 packets transmitted, 1 received, 0% packet loss, time 0ms rtt min/avg/max/mdev = 0.496/0.496/0.496/0.000 ms
Step 4: Run command set date 2024-06-23 12:00:00
at DUT0
and expect this output:
Step 5: Run command set date ntp 10.100.0.100
at DUT0
and check if output does not contain the following tokens:
skipping this serverShow output
Date was successfully updated!
Step 6: Run command show date
at DUT0
and check if output does not contain the following tokens:
Sun
Show output
Mon 24 Jun 2024 11:46:39 UTC +00:00
Step 7: Run command set date hwclock from-system update-drift debug
at DUT0
and expect this output:
Show output
hwclock from util-linux 2.33.1 System Time: 1719229599.742126 Trying to open: /dev/rtc0 Using the rtc interface to the clock. Last drift adjustment done at 1719229598 seconds after 1969 Last calibration done at 1719229598 seconds after 1969 Hardware clock is on UTC time Assuming hardware clock is kept in UTC time. Waiting for clock tick... ...got clock tick Time read from Hardware Clock: 2024/06/24 11:46:40 Hw clock time : 2024/06/24 11:46:40 = 1719229600 seconds since 1969 Time since last adjustment is 2 seconds Calculated Hardware Clock drift is 0.000000 seconds RTC type: 'rtc_cmos' Using delay: 0.500000 seconds 1719229600.500000 is close enough to 1719229600.500000 (0.000000 < 0.001000) Set RTC to 1719229600 (1719229600 + 0; refsystime = 1719229600.000000) Setting Hardware Clock to 11:46:40 = 1719229600 seconds since 1969 ioctl(RTC_SET_TIME) was successful. Not adjusting drift factor because it has been less than four hours since the last calibration. New /etc/adjtime data: 0.000000 1719229600 0.000000 1719229600 UTC
Step 8: Run command set date hwclock to-system debug
at DUT0
and expect this output:
Show output
hwclock from util-linux 2.33.1 System Time: 1719229600.612951 Trying to open: /dev/rtc0 Using the rtc interface to the clock. Last drift adjustment done at 1719229600 seconds after 1969 Last calibration done at 1719229600 seconds after 1969 Hardware clock is on UTC time Assuming hardware clock is kept in UTC time. Waiting for clock tick... ...got clock tick Time read from Hardware Clock: 2024/06/24 11:46:41 Hw clock time : 2024/06/24 11:46:41 = 1719229601 seconds since 1969 Time since last adjustment is 1 second Calculated Hardware Clock drift is 0.000000 seconds Calling settimeofday(1719229601.000000, 0)
Step 9: Run command show date
at DUT0
and check if output does not contain the following tokens:
Sun
Show output
Mon 24 Jun 2024 11:46:41 UTC +00:00