ntp

system ntp
SDE M10-Smart M2 RS420

Network Time Protocol (NTP) configuration

system ntp authenticate
SDE M10-Smart M2 RS420

Authenticate option

system ntp authenticate disable
SDE M10-Smart M2 RS420

Disable authentication (enabled by default)

system ntp authentication-key <u32>
SDE M10-Smart M2 RS420

Key ID used for authentication

Values
  • u32 – Key ID (1-65534)

Instances

Multiple

Required

system ntp authentication-key <u32> encrypted-md5 <password>
SDE M10-Smart M2 RS420
Values
  • password – Encrypted message for authentication

system ntp authentication-key <u32> md5 <txt>
SDE M10-Smart M2 RS420
Values
  • txt – Message for authentication

system ntp broadcast <ipv4|ipv6>
SDE M10-Smart M2 RS420

Broadcast/Multicast mode association “The IANA has assigned the multicast group address IPv4 224.0.1.1 and IPv6 ff05::101 exclusively to NTP”

Values
  • ipv4 – Broadcast/Multicast IP address

  • ipv6 – Broadcast/Multicast IPv6 address

Instances

Multiple

system ntp broadcast <ipv4|ipv6> key <u32>
SDE M10-Smart M2 RS420

Key ID used for authentication

Values
  • u32 – Key ID (1-65534)

system ntp broadcast <ipv4|ipv6> max-poll <u32>
SDE M10-Smart M2 RS420

Maximum poll interval in seconds as a power of two

Values
  • u32 – Maximum poll interval in seconds as a power of two (3-17)

system ntp broadcast <ipv4|ipv6> min-poll <u32>
SDE M10-Smart M2 RS420

Minimum poll interval in seconds as a power of two

Values
  • u32 – Minimum poll interval in seconds as a power of two (3-17)

system ntp broadcast <ipv4|ipv6> ttl <u32>
SDE M10-Smart M2 RS420

Time-to-life to use on broadcast/multicast server

Values
  • u32 – Time-to-life to use on broadcast/multicast server (0-7)

system ntp broadcast <ipv4|ipv6> version <u32>
SDE M10-Smart M2 RS420

NTP version used

Values
  • u32 – NTP versions allowed (1-4)

system ntp broadcast-client
SDE M10-Smart M2 RS420

Enables reception of broadcast server messages to any local interface

system ntp broadcast-delay <u32>
SDE M10-Smart M2 RS420

Network delay between the local and remote servers

Values
  • u32 – Delay in microseconds (3-7)

system ntp client
SDE M10-Smart M2 RS420

Network Time Protocol (NTP) client

system ntp client address <ipv4|ipv6>
SDE M10-Smart M2 RS420

IP address

Values
  • ipv4 – IP address

  • ipv6 – IPv6 address

Instances

Multiple

system ntp logging
SDE M10-Smart M2 RS420

NTP logging

Instances

Unique

system ntp logging all
SDE M10-Smart M2 RS420

Apply log level to all existing types.

system ntp logging type <txt>
SDE M10-Smart M2 RS420

Apply to specific log types.

Values
  • info – General information logs

  • events – General event logs

  • status – Status logs

  • statistics – Statistics logs

  • clock – Clock related logs

  • peer – Peer related logs

  • sys – System related logs

  • sync – Synchronization logs

Instances

List of values

system ntp master
SDE M10-Smart M2 RS420

Reference Clock

system ntp master prefer
SDE M10-Smart M2 RS420

Marks the Reference Clock as preferred

system ntp master stratum <u32>
SDE M10-Smart M2 RS420

Stratum number assigned to Reference Clock

Values
  • u32 – Stratum number (0-15)

system ntp multicast-client <ipv4|ipv6>
SDE M10-Smart M2 RS420

Enables reception of multicast server messages to the multicast group address(es) specified

Values
  • ipv4 – IP address

  • ipv6 – IPv6 address

Instances

Multiple

system ntp peer <ipv4|ipv6>
SDE M10-Smart M2 RS420

Network Time Protocol (NTP) peer

Values
  • ipv4 – IP address

  • ipv6 – IPv6 address

Instances

Multiple

system ntp peer <ipv4|ipv6> key <u32>
SDE M10-Smart M2 RS420

Key ID used for authentication

Values
  • u32 – Key ID (1-65534)

system ntp peer <ipv4|ipv6> local-address <ipv4|ipv6>
SDE M10-Smart M2 RS420

Local IP address to use as source for requests to this peer

Values
  • ipv4 – Local IPv4 address for this peer

  • ipv6 – Local IPv6 address for this peer

Local IP address

system ntp peer <ipv4|ipv6> local-interface <ifc>
SDE M10-Smart M2 RS420
Values
  • ifc – Interface to use as source for requests to this peer

system ntp peer <ipv4|ipv6> local-vrf <id>
SDE M10-Smart M2 RS420

VRF where socket is bound

Reference

system vrf <id>

system ntp peer <ipv4|ipv6> max-poll <u32>
SDE M10-Smart M2 RS420

Maximum poll interval in seconds as a power of two

Values
  • u32 – Maximum poll interval in seconds as a power of two (3-17)

system ntp peer <ipv4|ipv6> min-poll <u32>
SDE M10-Smart M2 RS420

Minimum poll interval in seconds as a power of two

Values
  • u32 – Minimum poll interval in seconds as a power of two (3-17)

system ntp peer <ipv4|ipv6> no-select
SDE M10-Smart M2 RS420

Marks the server as unused

system ntp peer <ipv4|ipv6> prefer
SDE M10-Smart M2 RS420

Marks the server as preferred

system ntp peer <ipv4|ipv6> version <u32>
SDE M10-Smart M2 RS420

NTP version used

Values
  • u32 – NTP versions allowed (1-4)

system ntp server
SDE M10-Smart M2 RS420

Network Time Protocol (NTP) server

system ntp server address <fqdn|ipv4|ipv6>
SDE M10-Smart M2 RS420
Values
  • fqdn – IP address or name of the server

  • ipv4 – IP address or name of the server

  • ipv6 – IP address or name of the server

Instances

Multiple

system ntp server address <fqdn|ipv4|ipv6> burst
SDE M10-Smart M2 RS420

Send a burst of eight packets when the server is reachable

system ntp server address <fqdn|ipv4|ipv6> key <u32>
SDE M10-Smart M2 RS420

Key-ID used for authentication

Values
  • u32 – Key ID (1-65534)

system ntp server address <fqdn|ipv4|ipv6> local-address <ipv4|ipv6>
SDE M10-Smart M2 RS420

Local IP address to use as source for requests to this server

Values
  • ipv4 – Local IPv4 address for this server

  • ipv6 – Local IPv6 address for this server

Local IP address

system ntp server address <fqdn|ipv4|ipv6> local-interface <ifc>
SDE M10-Smart M2 RS420
Values
  • ifc – Interface to use as source for requests to this server

system ntp server address <fqdn|ipv4|ipv6> local-vrf <id>
SDE M10-Smart M2 RS420

VRF where socket is bound

Reference

system vrf <id>

system ntp server address <fqdn|ipv4|ipv6> max-poll <u32>
SDE M10-Smart M2 RS420

Maximum poll interval in seconds as a power of two

Values
  • u32 – Maximum poll interval in seconds as a power of two (3-17)

system ntp server address <fqdn|ipv4|ipv6> min-poll <u32>
SDE M10-Smart M2 RS420

Minimum poll interval in seconds as a power of two

Values
  • u32 – Minimum poll interval in seconds as a power of two (3-17)

system ntp server address <fqdn|ipv4|ipv6> no-select
SDE M10-Smart M2 RS420

Marks the server as unused

system ntp server address <fqdn|ipv4|ipv6> preempt
SDE M10-Smart M2 RS420

Specifies the association as preemptable rather than the default persistent

system ntp server address <fqdn|ipv4|ipv6> prefer
SDE M10-Smart M2 RS420

Marks the server as preferred

system ntp server address <fqdn|ipv4|ipv6> version <u32>
SDE M10-Smart M2 RS420

NTP version used

Values
  • u32 – NTP versions allowed (1-4)

system ntp server dhcp
SDE M10-Smart M2 RS420

Enable configuration discovery via DHCP options

system ntp server dhcp interface <ifc>
SDE M10-Smart M2 RS420
Values
  • ifc – Enable configuration discovery via DHCP for specified interface

Instances

Multiple

system ntp trusted-key <u32>
SDE M10-Smart M2 RS420

Key(s) ID used for authentication

Values
  • u32 – Key ID (1-65534)

Instances

Multiple