netflow
- system netflow
- SDE
M10-Smart
M2
RS420
AresC640
Flow accounting settings
- Required:
- system netflow app-id
- SDE
M10-Smart
M2
RS420
AresC640
Collect and export app-id
- system netflow connmark
- SDE
M10-Smart
M2
RS420
AresC640
Connmark configuration and collect and export connmark
- system netflow connmark mark <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Choose a mark to identify connmark
- Instances:
Multiple
- system netflow connmark mark <u32> name <txt>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
txt – Name of connmark-tag
- system netflow connmark vrf-mark <id>
- SDE
M10-Smart
M2
RS420
AresC640
Choose a vrf mark to identify connmark
- Reference:
- Instances:
Multiple
- system netflow connmark vrf-mark <id> name <txt>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
txt – Name of connmark-tag
- system netflow debug <u32>
- SDE
M10-Smart
M2
RS420
AresC640
Debug verbosity level
- Values:
u32 – Level (0-4)
- system netflow destination <fqdn|ipv4|ipv6>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
fqdn – Export destination domain name
ipv4 – Export destination domain name
ipv6 – Export destination domain name
- Instances:
Multiple
- system netflow destination <fqdn|ipv4|ipv6> dont-verify-server
- SDE
M10-Smart
M2
RS420
AresC640
Dont check authentity of server certificates
- system netflow destination <fqdn|ipv4|ipv6> dtls
- SDE
M10-Smart
M2
RS420
AresC640
Encrypt netflow traffic
- system netflow destination <fqdn|ipv4|ipv6> port <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Destination port
- system netflow dns-host
- SDE
M10-Smart
M2
RS420
AresC640
Collect and export dns host
- system netflow engine-id <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Observation Domain ID
- system netflow exportcpu <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Lock exporter to this cpu
- system netflow hashsize <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Hash table size
- system netflow http-host
- SDE
M10-Smart
M2
RS420
AresC640
Collect and export http host
- system netflow http-ref
- SDE
M10-Smart
M2
RS420
AresC640
Collect and export http referer
- system netflow http-ua
- SDE
M10-Smart
M2
RS420
AresC640
Collect and export http user agent
- system netflow http-url
- SDE
M10-Smart
M2
RS420
AresC640
Collect and export http url
- system netflow local-address <ipv4|ipv6>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
ipv4 – Choose the output local address
ipv6 – Choose the output local address
- Local IP address:
- system netflow local-interface <ifc>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
ifc – Choose the output local interface
- system netflow local-vrf <id>
- SDE
M10-Smart
M2
RS420
AresC640
Choose the output local vrf
- Reference:
- system netflow mark <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Choose a number to mark netflow traffic
- system netflow maxflows <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Maximum number of flows
- system netflow protocol <id>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
id – Netflow protocol version
- system netflow refresh-rate <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – NetFlow v9/IPFIX refresh rate (packets)
- system netflow send-buffer <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Udp socket SNDBUF size (in bytes)
- system netflow ssl-server
- SDE
M10-Smart
M2
RS420
AresC640
Collect and export ssl server name identifier
- system netflow timeout
- SDE
M10-Smart
M2
RS420
AresC640
Netflow timeouts
- system netflow timeout active <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Active flows timeout in seconds
- system netflow timeout inactive <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – Inactive flows timeout in seconds
- system netflow timeout rate <u32>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
u32 – NetFlow v9/IPFIX timeout rate (minutes)
- system netflow vrf-mark <id>
- SDE
M10-Smart
M2
RS420
AresC640
Choose a vrf to mark netflow traffic
- Reference:
- Instances:
Multiple
- system netflow vrf-mark <id> name <id>
- SDE
M10-Smart
M2
RS420
AresC640
- Values:
id – Name of mark-tag