ignition
--------
.. osdx:cfgcmd:: service ignition
.. raw:: html
Devices
Configures the ignition-off powerdown timer for vehicle-mounted devices. When ignition is turned off, the device performs an orderly shutdown after the configured delay.
.. osdx:cfgcmd:: service ignition delay
.. raw:: html
Devices
Time (in minutes) the device stays on after ignition is turned off before performing orderly shutdown.
:arg u32:
Immediate shutdown on ignition loss (default) (0)
:arg u32:
Minutes the device stays on after ignition off (1-1440)
.. osdx:cfgcmd:: service ignition enable-snmp-trap
.. raw:: html
Devices
Enables sending of SNMP traps when ignition loss is detected.
.. osdx:cfgcmd:: service ignition log-level
.. raw:: html
Devices
Ignition monitor log-level
:arg emerg:
Emergency messages
:arg alert:
Urgent messages
:arg crit:
Critical messages
:arg err:
Error messages
:arg warning:
Warning messages
:arg notice:
Messages for further investigation
:arg info:
Informational messages
:arg debug:
Debug messages