Step 1: Set the following configuration in DUT1 :

set interfaces ethernet eth0 address 10.100.0.100/24
set protocols static route 0.0.0.0/0 next-hop 10.100.0.50
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
set system ntp master prefer
set system ntp master stratum 3

Step 2: Set the following configuration in DUT0 :

set interfaces ethernet eth0 address 10.100.0.50/24
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Step 3: Ping the IP address 10.100.0.100 from DUT0:

admin@DUT0$ ping 10.100.0.100 count 1 size 56 timeout 1
Show output
PING 10.100.0.100 (10.100.0.100) 56(84) bytes of data.
64 bytes from 10.100.0.100: icmp_seq=1 ttl=64 time=0.427 ms

--- 10.100.0.100 ping statistics ---
1 packets transmitted, 1 received, 0% packet loss, time 0ms
rtt min/avg/max/mdev = 0.427/0.427/0.427/0.000 ms

Step 4: Run the command set date 2026-06-02 12:00:00 on DUT0 and expect no output.

Step 5: Run the command set date ntp 10.100.0.100 on DUT0 and check whether the output does not contain the following tokens:

skipping this server
Show output
Date was successfully updated!

Step 6: Run the command show date on DUT0 and check whether the output does not contain the following tokens:

Tue
Show output
Wed 03 Jun 2026 11:51:36 +00:00

Step 7: Run the command set date hwclock from-system debug on DUT0 and expect the following output:

Show output
hwclock from util-linux 2.38.1
System Time: 1780487496.725025
Trying to open: /dev/rtc0
Using the rtc interface to the clock.
Last drift adjustment done at 1780487496 seconds after 1969
Last calibration done at 1780487496 seconds after 1969
Hardware clock is on UTC time
Assuming hardware clock is kept in UTC time.
RTC type: 'rtc_cmos'
Using delay: 0.500000 seconds
missed it - 1780487496.725367 is too far past 1780487496.500000 (0.225367 > 0.001000)
1780487497.500000 is close enough to 1780487497.500000 (0.000000 < 0.002000)
Set RTC to 1780487497 (1780487496 + 1; refsystime = 1780487496.000000)
Setting Hardware Clock to 11:51:37 = 1780487497 seconds since 1969
ioctl(RTC_SET_TIME) was successful.
Not adjusting drift factor because the --update-drift option was not used.
New /etc/adjtime data:
0.000000 1780487496 0.000000
1780487496
UTC

Step 8: Run the command set date hwclock to-system debug on DUT0 and expect the following output:

Show output
hwclock from util-linux 2.38.1
System Time: 1780487497.565742
Trying to open: /dev/rtc0
Using the rtc interface to the clock.
Last drift adjustment done at 1780487496 seconds after 1969
Last calibration done at 1780487496 seconds after 1969
Hardware clock is on UTC time
Assuming hardware clock is kept in UTC time.
Waiting for clock tick...
...got clock tick
Time read from Hardware Clock: 2026/06/03 11:51:38
Hw clock time : 2026/06/03 11:51:38 = 1780487498 seconds since 1969
Time since last adjustment is 2 seconds
Calculated Hardware Clock drift is 0.000000 seconds
Calling settimeofday(NULL, 0) to lock the warp_clock function.
Calling settimeofday(1780487498.000000, NULL) to set the System time.

Step 9: Run the command show date on DUT0 and check whether the output does not contain the following tokens:

Tue
Show output
Wed 03 Jun 2026 11:51:38 +00:00

Test RTC Synchronization With Drift

Description

Tests that RTC is working properly on machines that have an RTC device (while adjusting the drift too).

Scenario

Step 1: Set the following configuration in DUT1 :

set interfaces ethernet eth0 address 10.100.0.100/24
set protocols static route 0.0.0.0/0 next-hop 10.100.0.50
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
set system ntp master prefer
set system ntp master stratum 3

Step 2: Set the following configuration in DUT0 :

set interfaces ethernet eth0 address 10.100.0.50/24
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Step 3: Ping the IP address 10.100.0.100 from DUT0:

admin@DUT0$ ping 10.100.0.100 count 1 size 56 timeout 1
Show output
PING 10.100.0.100 (10.100.0.100) 56(84) bytes of data.
64 bytes from 10.100.0.100: icmp_seq=1 ttl=64 time=0.784 ms

--- 10.100.0.100 ping statistics ---
1 packets transmitted, 1 received, 0% packet loss, time 0ms
rtt min/avg/max/mdev = 0.784/0.784/0.784/0.000 ms

Step 4: Run the command set date 2026-06-02 12:00:00 on DUT0 and expect no output.

Step 5: Run the command set date ntp 10.100.0.100 on DUT0 and check whether the output does not contain the following tokens:

skipping this server
Show output
Date was successfully updated!

Step 6: Run the command show date on DUT0 and check whether the output does not contain the following tokens:

Tue
Show output
Wed 03 Jun 2026 11:51:46 +00:00

Step 7: Run the command set date hwclock from-system update-drift debug on DUT0 and expect the following output:

Show output
hwclock from util-linux 2.38.1
System Time: 1780487506.654196
Trying to open: /dev/rtc0
Using the rtc interface to the clock.
Last drift adjustment done at 1780487505 seconds after 1969
Last calibration done at 1780487505 seconds after 1969
Hardware clock is on UTC time
Assuming hardware clock is kept in UTC time.
Waiting for clock tick...
...got clock tick
Time read from Hardware Clock: 2026/06/03 11:51:47
Hw clock time : 2026/06/03 11:51:47 = 1780487507 seconds since 1969
Time since last adjustment is 2 seconds
Calculated Hardware Clock drift is 0.000000 seconds
RTC type: 'rtc_cmos'
Using delay: 0.500000 seconds
1780487507.500000 is close enough to 1780487507.500000 (0.000000 < 0.001000)
Set RTC to 1780487507 (1780487507 + 0; refsystime = 1780487507.000000)
Setting Hardware Clock to 11:51:47 = 1780487507 seconds since 1969
ioctl(RTC_SET_TIME) was successful.
Not adjusting drift factor because it has been less than four hours since the last calibration.
New /etc/adjtime data:
0.000000 1780487507 0.000000
1780487507
UTC

Step 8: Run the command set date hwclock to-system debug on DUT0 and expect the following output:

Show output
hwclock from util-linux 2.38.1
System Time: 1780487507.594784
Trying to open: /dev/rtc0
Using the rtc interface to the clock.
Last drift adjustment done at 1780487507 seconds after 1969
Last calibration done at 1780487507 seconds after 1969
Hardware clock is on UTC time
Assuming hardware clock is kept in UTC time.
Waiting for clock tick...
...got clock tick
Time read from Hardware Clock: 2026/06/03 11:51:48
Hw clock time : 2026/06/03 11:51:48 = 1780487508 seconds since 1969
Time since last adjustment is 1 second
Calculated Hardware Clock drift is 0.000000 seconds
Calling settimeofday(NULL, 0) to lock the warp_clock function.
Calling settimeofday(1780487508.000000, NULL) to set the System time.

Step 9: Run the command show date on DUT0 and check whether the output does not contain the following tokens:

Tue
Show output
Wed 03 Jun 2026 11:51:48 +00:00