Basic

These scenarios shows how to configure SNMP service and perform some requests to monitor basic system OIDs.

Test SNMP System Basic OIDs

Description

Scenario to check whether basic OIDs are included in telOSDxMonDBSystem MIB.

Scenario

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.27
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.24
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 9966
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Wed 19 Feb 2025 20:41:31 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 368384
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 10.03
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 9.14
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.29
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 422088
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 26.88
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1570512
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.2.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 2025-02-19 20:41:30.462948862 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 2025-02-19 20:41:30.473068992 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:

Test SNMP System Hardware Model

Description

Scenario to check whether hardware model OID is included in telOSDxMonDBSystem MIB.

Scenario

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModelOem.0 = STRING: Standard PC (i440FX + PIIX, 1996)