Basic
These scenarios shows how to configure SNMP service and perform some requests to monitor basic system OIDs.
Test SNMP System Basic OIDs
Description
Scenario to check whether basic OIDs are included in
telOSDxMonDBSystem
MIB.
Scenario
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem
and check if the
output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.18 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.20 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 1214 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Tue 18 Mar 2025 11:40:40 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 363676 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 3.31 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 3.93 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.10 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 364736 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 23.22 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1570512 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.2.3 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 2025-03-18 11:40:39.894936903 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 2025-03-18 11:40:39.903090834 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
Test SNMP System Hardware Model
Description
Scenario to check whether hardware model OID is
included in telOSDxMonDBSystem
MIB.
Scenario
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem
and check if the
output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModelOem.0 = STRING: Standard PC (i440FX + PIIX, 1996)