Basic
These scenarios shows how to configure SNMP service and perform some requests to monitor basic system OIDs.
Test SNMP System Basic OIDs
Description
Scenario to check whether basic OIDs are included in
the telOSDxMonDBSystem MIB.
Scenario
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.17 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.22 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 15013 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 19 Feb 2026 11:27:28 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 401628 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 3.93 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 2.71 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.55 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 431232 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 21.96 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1963708 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.8.4 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1771500447.826831 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1771500447.8313396 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModelOem.0 = STRING: Standard PC (i440FX + PIIX, 1996)
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.52 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.63 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 27765 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 19 Feb 2026 15:13:47 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 215202 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 16.53 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 11.35 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.73 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 489932 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 60.86 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 805076 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.8.4 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1771514023.518357 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1771514023.536816 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAAKZ-009748 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: M10-Smart-OSDx TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 47
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.57 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.70 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 28521 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 19 Feb 2026 15:55:10 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 215187 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 15.04 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 10.92 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.86 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 463884 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 25.31 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1832664 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.8.4 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1771516507.011377 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1771516507.0299916 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAALZ-026518 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: M2-OSDx TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansTag."1" = STRING: 1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansSpeed."1" = STRING: 2009 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTag.1 = INTEGER: 1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTemperature.1 = STRING: 54.000000 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 55
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.94 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 1.14 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 33737 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 19 Feb 2026 17:14:01 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 669730 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 43.42 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 37.87 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 1.41 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 469604 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 48.26 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 972992 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.8.4 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1771521233.877134 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1771521233.9169593 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAAXZ-000447 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: RS420
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.30 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.28 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 17939 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 19 Feb 2026 12:17:45 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 670235 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 2.82 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 1.97 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.33 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 635676 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 4.49 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 14157968 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.8.4 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1771503463.493360 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1771503463.5054233 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DABBZ-000102 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: Ares-C640 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansTag."1" = STRING: 1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansSpeed."1" = STRING: 660 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTag.1 = INTEGER: 1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTemperature.1 = STRING: 41.850000 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: true(1) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING: fail TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: true(1) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING: ok TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 42
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.21 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.25 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 14849 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 19 Feb 2026 11:24:54 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 1317180 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 1.44 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 1.89 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.28 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 609816 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 7.71 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 7910168 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.8.4 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1771500292.895252 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1771500292.9007962 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: AD132593N20004 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: SDE
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.40 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.41 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 19575 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 19 Feb 2026 12:48:16 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 215157 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 17.84 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 9.02 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.53 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 516848 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 13.52 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 3821476 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.8.4 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1771505294.755363 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1771505294.769054 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAASZ-013237 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: Atlas-840-OSDx TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: false(2) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: false(2) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 44
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.44 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.45 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 20188 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 19 Feb 2026 12:52:44 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 670168 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 16.33 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 8.60 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.54 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 542688 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 14.20 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 3821500 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.8.4 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1771505562.206104 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1771505562.2202122 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DABFZ-000107 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: M20-OSDx TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: false(2) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: false(2) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 49
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 4.08 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 4.13 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 27499 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 19 Feb 2026 14:58:02 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 670371 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 21.16 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 16.91 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 4.26 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 745232 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 40.76 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1828484 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.8.4 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1771513079.803871 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1771513079.818982 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DABDZ-009001 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: H5Rail-D-OSDx TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: true(1) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING: ok TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: true(1) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING: fail TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 44