internal-dying-gasp

service internal-dying-gasp
AresC640 Atlas840 H5-Rail M10-Smart M2 M20 RS420 RXL15000

Enables the internal Dying Gasp monitor that detects power supply failure via hardware signals.

service internal-dying-gasp delay <float>
AresC640 Atlas840 H5-Rail M10-Smart M2 M20 RS420 RXL15000

Time (in seconds) between the signal detection and the reboot of the device.

Values:
  • float – Seconds to delay the reboot. (0.0-60.0)

service internal-dying-gasp enable-snmp-trap
AresC640 Atlas840 H5-Rail M10-Smart M2 M20 RS420 RXL15000

Enables sending of SNMP traps related to the internal Dying Gasp monitor.

service internal-dying-gasp log-level <txt>
AresC640 Atlas840 H5-Rail M10-Smart M2 M20 RS420 RXL15000

Internal Dying Gasp log-level

Values:
  • emerg – Emergency messages

  • alert – Urgent messages

  • crit – Critical messages

  • err – Error messages

  • warning – Warning messages

  • notice – Messages for further investigation

  • info – Informational messages

  • debug – Debug messages