Basic
These scenarios shows how to configure SNMP service and perform some requests to monitor basic system OIDs.
Test SNMP System Basic OIDs
Description
Scenario to check whether basic OIDs are included in
the telOSDxMonDBSystem MIB.
Scenario
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.23 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.22 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 8631 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Mon 23 Mar 2026 10:48:52 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 419400 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 3.85 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 2.89 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.22 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 447484 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 28.45 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1572692 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1774262930.807073 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1774262930.812239 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModelOem.0 = STRING: Standard PC (i440FX + PIIX, 1996)
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.29 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.35 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 12326 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Mon 23 Mar 2026 17:49:40 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 208612 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 6.18 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 8.77 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.54 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 462840 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 25.26 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1832516 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1774288176.506592 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1774288176.5249019 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAAKZ-054768 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: M10-Smart-OSDx TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 49
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.34 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.35 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 2458 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Mon 23 Mar 2026 07:49:09 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 208333 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 13.42 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 11.26 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.38 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 426940 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 23.30 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1832536 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1774252145.510982 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1774252145.5295663 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAALZ-026518 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: M2-OSDx TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansTag."1" = STRING: 1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansSpeed."1" = STRING: 1951 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTag.1 = INTEGER: 1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTemperature.1 = STRING: 56.000000 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 57
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.49 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.74 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 9168 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Mon 23 Mar 2026 09:36:13 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 661756 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 40.88 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 38.38 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 1.07 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 341772 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 35.13 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 972864 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1774258565.397701 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1774258565.4362006 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAAXZ-000375 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: RS420
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.37 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.39 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 19112 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Wed 25 Mar 2026 01:39:33 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 642076 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 3.45 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 2.11 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.63 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 591164 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 4.18 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 14157840 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1774402771.342144 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1774402771.3542957 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DABBZ-000102 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: Ares-C640 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansTag."1" = STRING: 1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansSpeed."1" = STRING: 660 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTag.1 = INTEGER: 1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTemperature.1 = STRING: 41.850000 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: true(1) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING: fail TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: true(1) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING: ok TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 41
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.13 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.23 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 4228 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Mon 23 Mar 2026 08:04:56 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 1393396 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 0.89 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 0.70 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.79 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 629552 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 7.96 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 7905104 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1774253095.258071 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1774253095.263545 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: AD132593N20004 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: SDE
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.39 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.50 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 1066 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Mon 23 Mar 2026 07:19:11 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 208428 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 16.12 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 10.43 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.71 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 466776 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 12.21 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 3821348 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1774250349.702976 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1774250349.7163646 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAASZ-013237 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: Atlas-840-OSDx TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: false(2) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: false(2) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 44
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.37 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.45 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 39497 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Mon 23 Mar 2026 17:53:56 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 663786 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 9.09 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 8.00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.59 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 577984 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 15.13 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 3821376 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1774288434.874214 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1774288434.8881948 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
Step 1: Set the following configuration in DUT0 :
set service snmp community 'COMMUNITY2TEST!' set system advisor ADVISOR2TEST test ALARM2TEST set system alarm ALARM2TEST initial-state true set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'
Note
Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check
if the output includes the following lines:
Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 2.12 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 2.20 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 7076 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Mon 23 Mar 2026 08:58:07 +00:00 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 662666 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 13.44 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 7.78 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 2.42 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 497168 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 27.19 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1828360 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.1 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1774256285.597814 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1774256285.6121888 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING: TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DABDZ-009001 TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: H5Rail-D-OSDx TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: true(1) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING: ok TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: true(1) TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING: fail TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 43