Basic

These scenarios shows how to configure SNMP service and perform some requests to monitor basic system OIDs.

Test SNMP System Basic OIDs

Description

Scenario to check whether basic OIDs are included in the telOSDxMonDBSystem MIB.

Scenario

Step 1: Set the following configuration in DUT0 :

set service snmp community 'COMMUNITY2TEST!'
set system advisor ADVISOR2TEST test ALARM2TEST
set system alarm ALARM2TEST initial-state true
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.16
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.24
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 18972
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 16 Apr 2026 20:00:42 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 419592
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 5.17
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 5.11
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.43
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 453272
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 28.82
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1572696
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1776369640.755588
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1776369640.7602825
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModelOem.0 = STRING: Standard PC (i440FX + PIIX, 1996)

Step 1: Set the following configuration in DUT0 :

set service snmp community 'COMMUNITY2TEST!'
set system advisor ADVISOR2TEST test ALARM2TEST
set system alarm ALARM2TEST initial-state true
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.56
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.54
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 45110
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Fri 17 Apr 2026 03:23:07 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 209988
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 15.85
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 13.48
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.85
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 552244
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 30.14
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1832516
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1776396184.186645
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1776396184.2048943
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAAKZ-054768
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: M10-Smart-OSDx
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 54

Step 1: Set the following configuration in DUT0 :

set service snmp community 'COMMUNITY2TEST!'
set system advisor ADVISOR2TEST test ALARM2TEST
set system alarm ALARM2TEST initial-state true
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.47
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.62
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 11631
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 16 Apr 2026 19:08:53 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 209422
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 13.91
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 13.33
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.87
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 448088
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 24.45
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1832540
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1776366530.221616
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1776366530.2401483
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAALZ-026518
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: M2-OSDx
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansTag."1" = STRING: 1
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansSpeed."1" = STRING: 2047
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTag.1 = INTEGER: 1
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTemperature.1 = STRING: 62.000000
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 63

Step 1: Set the following configuration in DUT0 :

set service snmp community 'COMMUNITY2TEST!'
set system advisor ADVISOR2TEST test ALARM2TEST
set system alarm ALARM2TEST initial-state true
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.86
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 1.10
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 36597
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Fri 17 Apr 2026 06:49:58 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 668626
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 49.07
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 37.79
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 1.18
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 394168
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 40.52
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 972864
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1776408590.216485
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1776408590.254617
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAAXZ-000375
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: RS420

Step 1: Set the following configuration in DUT0 :

set service snmp community 'COMMUNITY2TEST!'
set system advisor ADVISOR2TEST test ALARM2TEST
set system alarm ALARM2TEST initial-state true
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.28
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.40
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 18007
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 16 Apr 2026 19:34:04 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 668809
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 3.21
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 2.38
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.63
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 622224
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 4.39
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 14157840
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1776368042.644687
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1776368042.656766
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DABBZ-000102
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: Ares-C640
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansTag."1" = STRING: 1
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemFansSpeed."1" = STRING: 720
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTag.1 = INTEGER: 1
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusThermalZoneTemperature.1 = STRING: 42.850000
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: true(1)
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING: fail
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: true(1)
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING: ok
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 42

Step 1: Set the following configuration in DUT0 :

set service snmp community 'COMMUNITY2TEST!'
set system advisor ADVISOR2TEST test ALARM2TEST
set system alarm ALARM2TEST initial-state true
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.09
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.11
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 4590
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 16 Apr 2026 15:53:18 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 1392628
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 4.49
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 2.53
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.08
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 573044
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 7.25
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 7905116
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1776354796.922886
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1776354796.9284751
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: AD132593N20005
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: SDE

Step 1: Set the following configuration in DUT0 :

set service snmp community 'COMMUNITY2TEST!'
set system advisor ADVISOR2TEST test ALARM2TEST
set system alarm ALARM2TEST initial-state true
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.37
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.43
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 14097
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Fri 17 Apr 2026 01:05:16 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 209354
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 16.18
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 10.67
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.41
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 508928
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 13.32
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 3821348
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1776387914.855534
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1776387914.8707266
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DAASZ-013237
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: Atlas-840-OSDx
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: false(2)
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: false(2)
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 49

Step 1: Set the following configuration in DUT0 :

set service snmp community 'COMMUNITY2TEST!'
set system advisor ADVISOR2TEST test ALARM2TEST
set system alarm ALARM2TEST initial-state true
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 0.25
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 0.15
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 16047
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Thu 16 Apr 2026 18:56:57 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 669230
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 4.01
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 4.18
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 0.09
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 516184
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 13.51
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 3821368
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1776365815.182677
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1776365815.1966689
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:

Step 1: Set the following configuration in DUT0 :

set service snmp community 'COMMUNITY2TEST!'
set system advisor ADVISOR2TEST test ALARM2TEST
set system alarm ALARM2TEST initial-state true
set system login user admin authentication encrypted-password '$6$GSjsCj8gHLv$/VcqU6FLi6CT2Oxn0MJQ2C2tqnRDrYKNF8HIYWJp68nvXvPdFccDsT04.WtigUONbKYrgKg8d6rEs8PjljMkH0'

Note

Execute the following command: service snmp walk local-agent v2c COMMUNITY2TEST! oid telOSDxMonDBSystem and check if the output includes the following lines:

Show output
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad15m.0 = STRING: 2.18
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad5m.0 = STRING: 2.27
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusUptime.0 = INTEGER: 7831
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusDate.0 = STRING: Fri 17 Apr 2026 03:52:47 +00:00
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusStorageUsed.0 = INTEGER: 667528
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu1m.0 = STRING: 5.58
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusCpu5m.0 = STRING: 8.14
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoad1m.0 = STRING: 2.47
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsed.0 = INTEGER: 491092
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusMemoryUsage.0 = STRING: 26.86
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusLoggedIn.0 = INTEGER: 2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemConntrackNumEntries.0 = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareMemory.0 = INTEGER: 1828352
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoOsVersion.0 = STRING: v4.2.9.2
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTag."ALARM2TEST" = STRING: ALARM2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdated."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmStatus."ALARM2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmTotalTimeUp."ALARM2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmToggleCount."ALARM2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmFirstToggle."ALARM2TEST" = STRING: 1776397965.797017
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAlarmUpdatedPrevious."ALARM2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTag."ADVISOR2TEST" = STRING: ADVISOR2TEST
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdated."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorStatus."ADVISOR2TEST" = STRING: true
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorTotalTimeUp."ADVISOR2TEST" = STRING: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorToggleCount."ADVISOR2TEST" = INTEGER: 0
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorFirstToggle."ADVISOR2TEST" = STRING: 1776397965.8116589
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemAdvisorUpdatedPrevious."ADVISOR2TEST" = STRING:
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareSerialNumber.0 = STRING: DABDZ-009001
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemInfoHardwareModel.0 = STRING: H5Rail-D-OSDx
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAPluggedIn.0 = INTEGER: true(1)
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyAStatus.0 = STRING: ok
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBPluggedIn.0 = INTEGER: true(1)
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusPowerSupplyBStatus.0 = STRING: fail
TELDAT-OSDX-MONDB-SYSTEM-MIB::telOSDxMonDBSystemStatusTemperature.0 = INTEGER: 48