ssm

service ssm
SDE M10-Smart M2 RS420 AresC640

System Service Monitoring (SSM) configuration

service ssm log-level <txt>
SDE M10-Smart M2 RS420 AresC640

SSM log-level

Values:
  • emerg – Emergency messages

  • alert – Urgent messages

  • crit – Critical messages

  • err – Error messages

  • warning – Warning messages

  • notice – Messages for further investigation

  • info – Informational messages

  • debug – Debug messages

service ssm operation <txt>
SDE M10-Smart M2 RS420 AresC640
Values:
  • txt – Operation id

Instances:

Multiple

Required:

service ssm operation <txt> alarm <txt>
SDE M10-Smart M2 RS420 AresC640

Operation’s alarms

“This node must have the name of an existing alarm”

Reference:

system alarm <txt>

Instances:

Multiple

Required:

service ssm operation <txt> alarm <txt> activate
SDE M10-Smart M2 RS420 AresC640

Operation’s thresholds to activate alarm

Instances:

Unique

service ssm operation <txt> alarm <txt> activate percentage <float>
SDE M10-Smart M2 RS420 AresC640

Percentage used as operation’s thresholds (only for types: cpu, memory and storage)

Only for types: cpu, memory and storage

Values:
  • float – Percentage used as operation’s thresholds to activate alarm (0-100)

service ssm operation <txt> alarm <txt> activate value <float>
SDE M10-Smart M2 RS420 AresC640

Value used as operation’s thresholds (only for types: memory, storage and temperature)

Float positive value (only for types: memory, storage and temperature)

Values:
  • float – Value used as operation’s thresholds to activate alarm

service ssm operation <txt> alarm <txt> deactivate
SDE M10-Smart M2 RS420 AresC640

Operation’s thresholds to deactivate alarm

Instances:

Unique

service ssm operation <txt> alarm <txt> deactivate percentage <float>
SDE M10-Smart M2 RS420 AresC640

Percentage used as operation’s thresholds (only for types: cpu, memory and storage)

Only for types: cpu, memory and storage

Values:
  • float – Percentage used as operation’s thresholds to deactivate alarm (0-100)

service ssm operation <txt> alarm <txt> deactivate value <float>
SDE M10-Smart M2 RS420 AresC640

Value used as operation’s thresholds (only for types: memory, storage and temperature)

Float positive value (only for types: memory, storage and temperature)

Values:
  • float – Value used as operation’s thresholds to deactivate alarm

service ssm operation <txt> description <txt>
SDE M10-Smart M2 RS420 AresC640
Values:
  • txt – Short description

service ssm operation <txt> interval <float>
SDE M10-Smart M2 RS420 AresC640
Values:
  • float

    Operation’s interval (s)

    Float positive value (s)

service ssm operation <txt> type <txt>
SDE M10-Smart M2 RS420 AresC640

Operation’s type

Values:
  • cpu – Use cpu-1m status

  • memory – Use memory-used status

  • storage – Use storage-used status

  • temperature – Use temperature status (only valid for devices with a temperature sensor)