ssm
- service ssm
 - SDE
M10-Smart
M2
RS420
System Service Monitoring (SSM) configuration
 
- service ssm log-level <txt>
 - SDE
M10-Smart
M2
RS420
SSM log-level
- Values
 emerg – Emergency messages
alert – Urgent messages
crit – Critical messages
err – Error messages
warning – Warning messages
notice – Messages for further investigation
info – Informational messages
debug – Debug messages
 
- service ssm operation <txt>
 - SDE
M10-Smart
M2
RS420
- Values
 txt – Operation id
- Instances
 Multiple
- Required
 
 
- service ssm operation <txt> alarm <txt>
 - SDE
M10-Smart
M2
RS420
Operation’s alarms “This node must have the name of an existing alarm”
- Reference
 - Instances
 Multiple
- Required
 
 
- service ssm operation <txt> alarm <txt> activate
 - SDE
M10-Smart
M2
RS420
Operation’s thresholds to activate alarm
- Instances
 Unique
 
- service ssm operation <txt> alarm <txt> activate percentage <float>
 - SDE
M10-Smart
M2
RS420
Percentage used as operation’s thresholds (only for types: cpu, memory and storage) Only for types: cpu, memory and storage
- Values
 float – Percentage used as operation’s thresholds to activate alarm (0-100)
 
- service ssm operation <txt> alarm <txt> activate value <float>
 - SDE
M10-Smart
M2
RS420
Value used as operation’s thresholds (only for types: memory, storage and temperature) Float positive value (only for types: memory, storage and temperature)
- Values
 float – Value used as operation’s thresholds to activate alarm
 
- service ssm operation <txt> alarm <txt> deactivate
 - SDE
M10-Smart
M2
RS420
Operation’s thresholds to deactivate alarm
- Instances
 Unique
 
- service ssm operation <txt> alarm <txt> deactivate percentage <float>
 - SDE
M10-Smart
M2
RS420
Percentage used as operation’s thresholds (only for types: cpu, memory and storage) Only for types: cpu, memory and storage
- Values
 float – Percentage used as operation’s thresholds to deactivate alarm (0-100)
 
- service ssm operation <txt> alarm <txt> deactivate value <float>
 - SDE
M10-Smart
M2
RS420
Value used as operation’s thresholds (only for types: memory, storage and temperature) Float positive value (only for types: memory, storage and temperature)
- Values
 float – Value used as operation’s thresholds to deactivate alarm
 
- service ssm operation <txt> description <txt>
 - SDE
M10-Smart
M2
RS420
- Values
 txt – Short description
 
- service ssm operation <txt> interval <float>
 - SDE
M10-Smart
M2
RS420
- Values
 float – Operation’s interval (s) Float positive value (s)
 
- service ssm operation <txt> type <txt>
 - SDE
M10-Smart
M2
RS420
Operation’s type
- Values
 cpu – Use cpu-1m status
memory – Use memory-used status
storage – Use storage-used status
temperature – Use temperature status