netflow
- system netflow
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Flow accounting settings
- Required:
 
 
- system netflow app-id
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Collect and export app-id
 
- system netflow connmark
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Connmark configuration and collect and export connmark
 
- system netflow connmark mark <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Choose a mark to identify connmark
- Instances:
 Multiple
 
- system netflow connmark mark <u32> name <txt>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 txt – Name of connmark-tag
 
- system netflow connmark vrf-mark <id>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Choose a vrf mark to identify connmark
- Reference:
 - Instances:
 Multiple
 
- system netflow connmark vrf-mark <id> name <txt>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 txt – Name of connmark-tag
 
- system netflow debug <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Debug verbosity level
- Values:
 u32 – Level (0-4)
 
- system netflow destination <fqdn|ipv4|ipv6>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 fqdn – Export destination domain name
ipv4 – Export destination domain name
ipv6 – Export destination domain name
- Instances:
 Multiple
 
- system netflow destination <fqdn|ipv4|ipv6> dont-verify-server
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Dont check authentity of server certificates
 
- system netflow destination <fqdn|ipv4|ipv6> dtls
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Encrypt netflow traffic
 
- system netflow destination <fqdn|ipv4|ipv6> port <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Destination port
 
- system netflow dns-host
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Collect and export dns host
 
- system netflow engine-id <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Observation Domain ID
 
- system netflow exportcpu <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Lock exporter to this cpu
 
- system netflow hashsize <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Hash table size
 
- system netflow http-host
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Collect and export http host
 
- system netflow http-ref
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Collect and export http referer
 
- system netflow http-ua
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Collect and export http user agent
 
- system netflow http-url
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Collect and export http url
 
- system netflow local-address <ipv4|ipv6>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 ipv4 – Choose the output local address
ipv6 – Choose the output local address
- Local IP address:
 
 
- system netflow local-interface <ifc>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 ifc – Choose the output local interface
 
- system netflow local-vrf <id>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Choose the output local vrf
- Reference:
 
 
- system netflow mark <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Choose a number to mark netflow traffic
 
- system netflow maxflows <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Maximum number of flows
 
- system netflow protocol <id>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 id – Netflow protocol version
 
- system netflow refresh-rate <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – NetFlow v9/IPFIX refresh rate (packets)
 
- system netflow send-buffer <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Udp socket SNDBUF size (in bytes)
 
- system netflow ssl-server
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Collect and export ssl server name identifier
 
- system netflow timeout
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Netflow timeouts
 
- system netflow timeout active <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Active flows timeout in seconds
 
- system netflow timeout inactive <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – Inactive flows timeout in seconds
 
- system netflow timeout rate <u32>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 u32 – NetFlow v9/IPFIX timeout rate (minutes)
 
- system netflow vrf-mark <id>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
Choose a vrf to mark netflow traffic
- Reference:
 - Instances:
 Multiple
 
- system netflow vrf-mark <id> name <id>
 - AresC640
Atlas840
M10-Smart
M2
RS420
RXL15000
SDE
- Values:
 id – Name of mark-tag